AS150DRL DIN Rail Mount Power Supplies – Switch Mode Enclosed 150w 150 Watt

150W Single Output Switching Power Supply

  • AC input range selectable by switch
  • Protections: Short circuit/Over load/Over voltage
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at 25KHz


Model Number
Output Voltage
Output Amps
Load Regulation
Line Regulation
Ripple and Noise
AS150-5/DRL5V30A+/- 0.5%+/- 0.5%150mVp-p max. (Note 2)
AS150-7.5/DRL7.5V20A+/- 0.5%+/- 0.5%150mVp-p max. (Note 2)
AS150-9/DRL9V16.7A+/- 0.3%+/- 0.3%180mVp-p max. (Note 2)
AS150-12/DRL12V12.5A+/- 0.3%+/- 0.3%180mVp-p max. (Note 2)
AS150-13.5/DRL13.5V11.2A+/- 0.3%+/- 0.3%180mVp-p max. (Note 2)
AS150-15/DRL15V10A+/- 0.3%+/- 0.3%180mVp-p max. (Note 2)
AS150-24/DRL24V6.5A+/- 0.2%+/- 0.2%240mVp-p max. (Note 2)
AS150-27/DRL27V5.6A+/- 0.2%+/- 0.2%240mVp-p max. (Note 2)
AS150-48/DRL48V3.2A+/- 0.2%+/- 0.2%240mVp-p max. (Note 2)
Model Number
Over Voltage Protection
Voltage Tolerance
DC Voltage Adjust
Minimum Load Requirement
Efficiency
AS150-5/DRL5.75 ~ 6.75V Shut down o/p voltage, re-power on to recover+/- 2.0% (Note 3)4.5 ~ 5.5V0 ~ 30A78% typ.
AS150-7.5/DRL8.63 ~ 10.13V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)6 ~ 8.3V0 ~ 20A80% typ.
AS150-9/DRL10.35 ~ 12.2V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)8 ~ 10.4V0 ~ 16.7A80% typ.
AS150-12/DRL13.8 ~ 16.2V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)10.6 ~ 13.2V0 ~ 12.5A82% typ.
AS150-13.5/DRL15.53 ~ 18.2V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)12 ~ 15V0 ~ 11.2A83% typ.
AS150-15/DRL17.25 ~ 20.3V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)13.5 ~ 16.5V0 ~ 10A84% typ.
AS150-24/DRL30 ~ 34.8V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)21 ~ 28V0 ~ 6.5A85% typ.
AS150-27/DRL31.1 ~ 36.45V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)24 ~ 30V0 ~ 5.6A86% typ.
AS150-48/DRL55.2 ~ 64.8V Shut down o/p voltage, re-power on to recover+/- 1.0% (Note 3)43 ~ 53V0 ~ 3.2A87% typ.

AS150/DRL series

Input Specifications

Input Voltage Range 88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC
Frequency Range 47 ~ 63Hz
Inrush Current Cold Start 35A typ.
Input Current 3.2A/115VAC 1.6A/230VAC typ.
Leakage Current <3.5mA / 240 VAC

General Specifications

Isolation 3KVAC
Isolation Input-Ground 1.5KVAC
Isolation Output-Ground 0.5KVAC
Insulation Resistance 100M Ohms/500VDC
Efficiency 78% typ.
Safety Approvals UL1012, UL60950-1, TUV EN60950-1 Approved
Harmonic Current Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature -10°C ~ +60°C (Refer to output load for derating curve)
Storage Temperature -20°C ~ +85°C
Working Humidity 20~90% RH non condensing
Storage Humidity 10 ~ 95% RH
EMI Compliance to EN 55022 (CISPR22) Class B
MTBF 286.7K hrs min. MIL-HDBK-217F (25°C)
Vibration 10 ~ 500Hz. 2G 10- min./1 cycle, 60min. Each along X, Y, Z axes
EMS Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A

Output Specifications

Output Voltage 5V
Output Amps 30A
Load Regulation ± 0.5%
Line Regulation ± 0.5%
Temperature Coefficient ±0.03%/°C (0 ~ 50°C)
Ripple and Noise 150mVp-p max. (Note 2)
Over Voltage Protection 5.75 ~ 6.75V Shut down o/p voltage, re-power on to recover
Over Current Protection 105 ~ 150% rated output power Shut down o/p voltage, re-power on to recover
Voltage Tolerance ± 2.0% (Note 3)
DC Voltage Adjust 4.5 ~ 5.5V
Minimum Load Requirement 0 ~ 30A
Rise Time 100ms, 50ms at full load
Hold Up Time 28ms at full load typ.

Physical Specifications

Size (mm) 199x110x50mm
Size (Inches) 7.8×4.3×1.9”
Weight (g) 0.8KG; 16pcs/13.8KG/0.95CUFT

Notes

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.
  2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

2014 © Astrodyne Power Supplies | Sitemap | Privacy Policy