CLG60-12
   
Output Voltages12
Output Watts60
Input Voltage Range90-264VAC
UL/C-ULUL1310 Class 2
Size (inches)7.70" x 2.42" x 1.53"
 PDF Data-Sheet
Back
Customize This Part
   
   
# of Outputs1
Output Voltage12
Output Amps5
InputAC
Input Amps0.8
Leakage Current0.75mA
Frequency Range47-63Hz
Power Factor0.9
Inrush Current (typ)40 Amps @ 230VAC
Over Temp Protection90°C±10°C
Over Current Protection95~110%
Over Voltage Protection13.8~16 Volts
DC Voltage Adjust (typ)11.5~13Volts
Short Circuit ProtectionHiccup mode, auto recov
Ripple/Noise2 Vpk-pk
Temperature Coefficient±0.03%/°C (0~50°C)
Line Regulation±3.0%
Load Regulation±5.0%
Switching Frequency90 KHz
Input-Output Isolation3.75K VAC
I/P-Ground1.88K VAC
O/P-Ground500 VAC
Isolation Resistance100MO / 500VDC /25°C/70% RH
Efficiency0.81
Operating Temp-30°C to +70°C
Storage Temperature-40°C to +80°C, 10~95% RH
Relative Humidity20~95% RH non cond
MTBF495.7KHrs min, MIL-HDBK-217F(25°C)
Shock/Vibration10~500Hz, 5G 12min./1cycle,. period for 72min, each along X, Y. Z axes
EMCEN55022 Level B
CoolingFree air convection
TUVTUV EN61347-1, EN61347-2-13,
CSACAN/CSA C22.2 No. 223-M91(except for 48V)
Weatherability StandardIP67
Size (mm)195.6 x 61.5 x 38.8
Weight (g)860
Size (inches)7.70" x 2.42" x 1.53"
Weight (Oz)30.34
Mounting and ConnectionFlying Leads
Part DescCLG60-12
Weight (LBS)1.9
Price(1-9)$109.20
Price(10+)$89.25