Model Number |
Input Voltage Range |
Output Voltage |
Output Amps |
Load Regulation |
Voltage Balance |
|
9-36VDC |
5 VDC |
0.5Amps |
±0.2% |
||
|
18-72VDC |
5 VDC |
0.5Amps |
±0.2% |
||
|
9-36VDC |
12 VDC |
0.25Amps |
±0.2% |
||
|
18-72VDC |
12 VDC |
0.25Amps |
±0.2% |
||
|
9-36VDC |
15 VDC |
0.2Amps |
±0.2% |
||
|
18-72VDC |
15 VDC |
0.2Amps |
±0.2% |
||
|
9-36VDC |
±5 VDC |
±0.25Amps |
±1% 25% - FL |
±2% |
|
|
18-72VDC |
±5 VDC |
±0.25Amps |
±1% 25% - FL |
±2% |
|
|
9-36VDC |
±12 VDC |
±0.125Amps |
±1% 25% - FL |
±2% |
|
|
18-72VDC |
±12 VDC |
±0.125Amps |
±1% 25% - FL |
±2% |
|
|
9-36VDC |
±15 VDC |
±0.1Amps |
±1% 25% - FL |
±2% |
|
|
18-72VDC |
±15 VDC |
±0.1Amps |
±1% 25% - FL |
±2% |
VKC03 series
|
Input Specifications
General Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |
Output Specifications
Environmental Specifications
|