Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

UV300T 300 Watt Power Converters

MicroVerter® Series

High Reliability/COTS DC/DC Converters

Miniature Size

High Density - Up to 58 W/in.3

Constant Frequency - 370 kHz

Parallelable with Current Sharing

Fault Tolerant - n+m Redundancy

Non-Shutdown OVP

Extremely Low Thermal Resistance

Model Number

Output Voltage

Output Amps

UV300-T512 5 Volts / 12 Volts / -12 Volts (DC) 35 Amps* / 3 Amps* / 3 Amps*
UV300-T515 5 Volts / 15 Volts / -15 Volts (DC) 35 Amps* / 3 Amps* / 3 Amps*

*Maximum Total Output Power 185 Watts

  Multiple Configurations Available
S= Synchronization 330-400KHz
T= -55°C to 100°C Operating Temperature
C= Conformal Coating
E= -55°C to 125°C Operating Temperature (Consult tech@astrodyne.com for output power rating)
RL= No Pure Tin
LF= RoHS Compliant
  (ex. UV300-T515-STCRL)

UV300 Triple series

Input Specifications

Input Voltage (+In to -In)

300VDC±80VDC, 400VDC max.

Brownout

180VDC typ. (75% full output)

In Rush Charge 4.5 x 10-5 Coulombs typ.
Input Reflected Ripple 20% typ. (full load, nominal line)
No Load Power Dissipation 7.5 watts
Logic Disabled Power In 1 watt

Input Ripple Rejection

60dB @120Hz, typ.

General Specifications

Input/Output Isolation

45000VDC, min. (consult factory for procedure)

Input/Baseplat Isolation

2500VDC, min.

Output/Baseplate Isolation

500VDC, min.

Input-to-Output Capacitance

5700pF typ.

Environmental Specifications

Operating Temperature

-40°C to +100°C

Thermal Resistance Case to Ambient

3.3°C/w typ. (single @ Tc=100°C)

Output Specifications

Output Voltage

See Selection Chart Above

Watts 252 Watts
Set Point Accuracy ±0.5% typ., ±1% max. (10A on main, no load auxilaries)

Load Regulation

0.2% typ., 0.5% max (0 to Full Load)

Line Regulation

0.01% typ., 0.1% max. (Over Range)

Ripple

.25% typ., 0.5% p-p max. (0 to 20MHz)

Output Power

See Selection Chart Above

Current Limit (auto. recovery)

110-120% typ. (full load)

Current Sharing (automatic)

±5% typ. (full load)

Transient Response

200µs typ. (20-80% load, Vout within 1%), 200µs typ. (low line to high line, Vout 1%), 200µs typ. (50-100% load, Vout 1%)

Temp Drift .06%/°C typ.
Over Temperature Shut-Down 105°C ± 5°C (Case Temperature)
Turn-On Time 250 msec, typ. (input power aplied, Vout 1%)
Enable Current (Logic Off) 1.0 mA, typ. (sink)
Turn-On Time 2msec, typ. (Vout within 1%)

Physical Specifications

Size (mm)

1.3 x 6.1 x 11.7 mm

Size (Inches)

0.5”x 2.4”x 4.6”

Weight (g)

255.1 g

Weight (oz)

9 oz