Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

UV300 300 Watt Power Converters

UV300 300 Watt  Power Converters

MicroVerter® Series

High Reliability/COTS DC/DC Converters

Miniature Size

High Density- Up to 58 W/in.3

Constant Frequency- 370 kHz

Parallelable with Current Sharing

Fault Tolerant - n+m Redundancy

Non-Shutdown OVP

Extremely Low Thermal Resistance

Model Number

Output Voltage

Output Amps

UV300-5 5vdc 40 Amps
UV300-8 8vdc 30 Amps
UV300-12 12vdc 20 Amps
UV300-15 15vdc 16 Amps
UV300-24 24vdc 10 Amps
UV300-28 28vdc 9 Amps
  Multiple Configurations Available
S= Synchronization 330-400KHz
T= -55°C to 100°C Operating Temperature
C= Conformal Coating
E= -55°C to 125°C Operating Temperature (Consult tech@astrodyne.com for output power rating)
RL= No Pure Tin
LF= RoHS Compliant
  (ex. UV300-12-STCRL)

 

UV300 series

Input Specifications

Input Voltage (+In to -In),

300VDC ± 80VDC, 400VDC max.

Brownout

180VDC (75% full output)

In Rush Charge 4.5 x 10-5 Coulombs typ.
Input Reflected Ripple 20% typ. (full load, nominal line)
No Load Power Dissipation 2.5 watts
Logic Disabled Power In 1 watt

Input Ripple Rejection

60dB @120Hz, typ.

General Specifications

Input/Output Isolation

45000VDC, min. (consult factory for procedure)

Input/Baseplat Isolation

2500VDC, min.

Output/Baseplate Isolation

500VDC, min.

Input-to-Output Capacitance

5700pF typ.

Environmental Specifications

Operating Temperature

-40°C to +100°C

Thermal Resistance Case to Ambient

4.2°C/w typ.(single @ Tc=100°C)

Output Specifications

Output Voltage

See Selection Chart Above

Watts 252 Watts
Set Point Accuracy ±1% max. (no load)

Load Regulation

0.02% typ., 0.2% max (0 to Full Load)

Line Regulation

0.02% typ., 0.2% max. (Over Range)

Ripple

1% typ., 3% p-p max. (0 to 20MHz)

Output Power

See Selection Chart Above

Current Limit (auto. recovery)

110-120% typ. (full load)

Current Sharing (automatic)

±5% (full load)

Transient Response Singles

50µs typ.(20-80% load, .5A/µs, Vout 1%)

Transient Response Main Output Triples

200µs min. (10-20A, aux. loads 2.5A, .25A/µs, Vout 1%)
Transient Response Waveforms See website: www.roassoc.com
Temp Drift .02%/°C max.
Trim Range ±10% min. (consult factory for extended range)
Remote Sense Compensation 0.5V max. (total)
Over voltage Protection (Non-Shutdown, Auto Recovery) 120% typ. (or Vout +5 whichever is greater)
Over Temperature Shut-Down 105°C ± 5°C (Case Temperature)
Turn-On Time 250 msec, typ. (input power aplied, Vout 1%)
Enable Current (Logic Off) 1.0 mA, typ. (sink)
Turn-On Time 2msec, typ. (Vout within 1%)

Physical Specifications

Size (mm)

1.3 x 6.1 x 9.1 mm

Size (Inches)

0.5”x 2.4”x 3.6”

Weight (g)

198.4 g

Weight (oz)

7 oz

Notes