TS1500 1500 Watt Power Supplies
|
True sine wave output (THD<3%) |
|
|
High surge power up to 3000W |
|
|
High efficiency up to 91% |
|
|
Power ON-OFF switch |
|
|
Standby saving mode can be selectable |
|
|
Front panel indicator for operation status |
|
Model Number |
Input Voltage Range |
Efficiency |
Input Fuse |
Battery Low Alarm |
Battery Low Shutdown |
Over Temperature Protection |
|
12vdc |
87% |
40Amps*5 |
11.3±4% |
10.5±4% |
82°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor |
|
|
24 Volts(DC |
89% |
30Amps*3 |
22.5±4% |
21±4% |
82°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor |
|
|
48vdc |
90% |
30Amps*2 |
45±4% |
42±4% |
96°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor |
TS1500 series
|
Input Specifications
General Specifications
Physical Specifications
|
Output Specifications
Environmental Specifications
Notes 1.Output derating capacity referenced by curve 1. 2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Output derating capacity referenced by curve 2. 4.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |