TP150DRL 150w Power Supplies

150W Triple Output with PFC Function

Universal AC input/full range

Built-in active PFC function, PF>0.94

Protections: Short circuit/Over load/Over voltage

Forced Air Cooling by built-in DC fan

Fixed switching frequency at 100KHz

Model Number

Output Voltage

Output Amps

Ripple and Noise

Voltage Tolerance

Minimum Load Requirement

Efficiency

TP150-A

5V, 12V, -5V

15A, 6A, 0.6A

100mVp-p max., 120mVp-p max., 100mVp-p max. (Note 2)

+/-3.0%, +/-8.0%, +/-6.0% (note 3)

2~20A, 0.4~7A, 0~1A

75% typ.

TP150-B

5V, 12V, -12V

15A, 5.5A, 0.6A

100mVp-p max., 120mVp-p max., 100mVp-p max. (Note 2)

+/-3.0%, +/-8.0%, +/-6.0% (note 3)

2~20A, 0.4~7A, 0~1A

77% typ.

TP150-C

5V, 15V, -15V

15A, 4.5A, 0.6A

100mVp-p max., 150mVp-p max., 100mVp-p max. (Note 2)

+/-3.0%, +/-10, -6%, +/-6.0% (note 3)

2~20A, 0.4~6A, 0~1A

77% typ.

TP150-D

5V, 24V, 12V

15A, 3A, 0.6A

100mVp-p max., 150mVp-p max., 100mVp-p max. (Note 2)

+/-3.0%, +/-8.0%, +/-6.0% (note 3)

2~20A, 0.4~4A, 0~1A

78% typ.

TP150/DRL series

Input Specifications

General Specifications

Isolation

3KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

75% typ.

Safety Approvals

UL60950-1, TUV EN60950-1 Approved (Note 4)

Harmonic Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Input Voltage Range

90~264VAC 127~370VDC

Frequency Range

47~63Hz

Inrush Current

Cold Start ?40A/230V typ.

Input Current

2.5A/115VAC 1.2A/230VAC typ

Leakage Current

<3.5mA/240VAC

Power Factor Correction

PF>0.94/230VAC PF>0.98/115VAC at Full Load typ

Operating Temperature

-10~+60°C (Refer to output load derating curve)

Storage Temperature

-20~+85°C

Working Humidity

20 ~ 90 % RH non-condensing

Storage Humidity

10~95% RH

EMI

Compliance to EN55022 (CISPR22) Class B (Note 4)

MTBF

161.6K hrs. min MIL-HDBK-217F (25°C)

Vibration

10~500HZ, 2G 10 min/1 cycle, 60 min. each along X, Y, Z axes

EMS

Compliance to EN-61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A (Note 4)

Output Specifications

Output Voltage

5V

Output Amps

15A

Load Regulation

±3.0%

Line Regulation

±1%

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

5.75~6.75V on +5V. Protection type: Shutdown o/p voltage, re-power on to recover.

Over Current Protection

105~150% rated output power. Protection type: Hiccup mode, recovers automatically after fault condition is removed.

Over Temperature Protection

95°C ±5°C (TSW1). Protection type: shot down o/p voltage, recovers automatically after temperature goes down.

Voltage Tolerance

±3% (Note 3)

DC Voltage Adjust

4.75~5.5V

Minimum Load Requirement

2~20A

Rise Time

800ms, 60ms/230VAC; 800ms, 60ms/115VAC at full load

Hold Up Time

24ms/230VAC 24ms/115VAC at full load typ.

Size (mm)

199mm x 99mm x 50mm

Weight (g)

0.9Kg; 20pcs/19Kg/1.28CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Physical Specifications

Notes