Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

TP100DRL 100 Watt DIN Rail Mount Power Supplies

100W Triple Output with PFC Function

Universal AC input/full range

Built-in active PFC function, PF>0.94

Protections: Short circuit/Over load/Over voltage

Free air cooling convection

Fixed switching frequency at 100KHz (Optional)

Model Number

Output Voltage

Output Amps

Voltage Tolerance

Minimum Load Requirement

Efficiency

TP100-A

5V, 12V, -5V

10A, 4A, 0.6A

+/-3.0%,+/-7.0%, +/-6.0% (Note 3)

3~15A, 0.4~5A, 0~1A

75% typ.

TP100-B

5V, 12V, -12V

10A, 4A, 0.6A

+/-3.0%,+/-6.0%, +/-6.0% (Note 3)

3~15A, 0.4~5A, 0~1A

78% typ.

TP100-C

5V, 15V, -15V

10A, 3A, 0.6A

+/-3.0%,+10,-6.%, +/-6.0% (Note 3)

3~15A, 0.4~4A, 0~1A

77% typ.

TP100-D

5V, 24V, 12V

10A, 2A, 0.6A

+/-3.0%,+/-8.0%, +/-6.0% (Note 3)

3~15A, 0.4~3A, 0~1A

78% typ.

TP100/DRL series

Input Specifications

Input Voltage Range

90-264VAC 127~370VDC (Note 5)

Frequency Range

47~63Hz

Inrush Current

Cold Start ?40A/230V typ.

Input Current

1.5A/115VAC 0.75A/230VAC

Leakage Current

<3.5mA/240VAC

Power Factor Correction

PF>0.94/230VAC PF>0.98/115VAC at Full Load typ.

Isolation

3KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

75% typ.

Safety Approvals

UL60950-1, TUV EN60950-1 Approved (Note 4)

Harmonic Current

Compliance to EN61000-3-2,-3 (Note 4)

Operating Temperature

-10~+60°C (Refer to output load derating curve)

Storage Temperature

-20~+85°C

Working Humidity

20 ~ 90 % RH non-condensing

Storage Humidity

10~95% RH

EMI

Compliance to EN55022 (CISPR22) Class B (Note 4)

MTBF

170.1K hrs. min MIL-HDBK-217F (25°C)

Vibration

10~500HZ, 2G 10 min/1 cycle, 60 min. each along X, Y, Z axes

EMS

Compliance to EN-61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A (Note 4)

General Specifications

Environmental Specifications

Output Specifications

Output Voltage

5V

Output Amps

10A

Load Regulation

±3.0%

Line Regulation

±1%

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

CH1: 5.75~6.75V on 5V. Protection type: Shut down o/p voltage, re-power on to recover

Over Current Protection

105~150% rated output power. Protection type: Hiccup mode, recovers automatically after fault condition is removed.

Over Temperature Protection

95°C ±5°C (TSW1). Protection type: shot down o/p voltage, recovers automatically after temperature goes down.

Voltage Tolerance

±3.0% (Note 3)

DC Voltage Adjust

4.75~5.5V

Minimum Load Requirement

3~15A

Rise Time

800ms, 60ms/230VAC; 800ms, 60ms/115VAC at full load

Hold Up Time

24ms/230VAC 24ms/115VAC at full load typ.

Physical Specifications

Size (mm)

199mm x 99mm x 50mm

Weight (g)

0.83Kg; 20pcs/17.6Kg/1.28CUFT

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.