Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

TN1500 1500w Power Supplies

TN1500 1500w  Power Supplies

1500W True Sine Wave DC-AC Inverter with Solar Charger

True sine wave output

High surge power up to 3000W

High efficiency up to 91%

Power ON-OFF switch

Standby saving mode can be selectable

Front panel indicator for operation status

Model Number

Input Voltage Range

Input Fuse

Battery Low Alarm

Battery Low Shutdown

Over Temperature Protection

Max Open Circuit Voltage

TN1500-112F

12 Volts(DC)

40Amps*5

11.3±4%

10.5±4%

82°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor

25Volts(DC)

TN1500-124F

24 Volts(DC

30Amps*3

22.5±4%

21±4%

82°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor

45Volts(DC)

TN1500-148F

48 Volts(DC)

30Amps*2

45±4%

42±4%

96°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor

75Volts(DC)

TN1500 series

Input Specifications

Input Voltage Range

12 Volts(DC)

No Load Power Consumption

? 18W @ standby saving mode

Off Mode Current Draw

? 1 mAmps

Battery Types

Open & sealed lead Acid

Efficiency

89%

Input Fuse

40Amps*5

Battery Low Alarm

11.3±4%

Battery Low Shutdown

10.5±4%

Reverse Polarity

By internal fuse open

General Specifications

Isolation

3000VAC Bat I/P - AC O/P 3000VAC Bat I/P - AC I/P

Output-Ground Isolation

1500VACAC O/P - FG

Insulation Resistance

AC O/P-FG, Bat I/P-FG: 100M?/500VDC/25°C/70% RH

Safety Approvals

UL458(only “GFCI” receptacles types F)

Physical Specifications

Size (mm)

420 x 220 x 88

Size (Inches)

16.53” x 8.66” x 3.46”

Control Wiring

RJ11-RS232 (option)

Weight (g)

6850g

Weight (oz)

241.63 oz

Notes

1.Output derating capacity referenced by curve 1.

2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.

3.Output derating capacity referenced by curve 2.

4.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Specifications

Output Voltage

100/110/115/120VAC select by S.W

Frequency Range

60 0.1Hz 50/60Hz select by S.W

Peak Load

1725W for 180S/2250W for 10S /surge power 3000W for 30 cycles

Waveform

True sine wave (THD<3%) at rated input voltage

Load Regulation

±3.0%

Saving Mode

Load ?5W changed to standby mode

Front Panel Indicator

Battery voltage level, output load level, saving mode, fault and operation status

Circuit Breaker

TN-1500-1xx: 20A ; TN-1500-2xx:10A

GFCI Protection

TN-1500-1xx: Optional (Only type F)

Transfer Time

t <10mS inverter by pass

Over Current Protection

105~115% for 180S,115~150% for 10S Shutdown o/p voltage, re-power

Over Temperature Protection

82°C±5°C Shutdown o/p voltage, repower after cool down; by internal RTH3 detect on heatsink of power transistor

Short Circuit Protection

Shutdown o/p voltage, re-power

AC/Solar Charger

TN-1500-112/212: 14.3Volts(DC)±4%

Max Open Circuit Voltage

25Volts(DC)

Charge Current

30 Amps

Environmental Specifications

Operating Temperature

0°C to +40°C @ 100% load 60°C @ 50% load

Vibration

10~500Hz, 3G10min./1cycle, period for 60min. each along X, Y, Z axes

Storage Temperature

-30°C ~ +70°C /-22~+158°F 10~95% RH

Relative Humidity

20 to +90% RH non cond

EMI

Compliance to FCC class A

Cooling

Thermostatically controlled cooling fan