Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU80 80 Watt Power Supplies

80 Watt Desktop Switching Power Supplies with PFC

Input Voltage 90 to 264 VAC

IEC-320-C14 Input Inlet

Power Factor correction

Splash Proof Case

CEC and LPS Energy Efficiency Level V

Model Number

Output Voltage

Output Amps

SPU80-105

12vdc

6.66 Amps

SPU80-106

15vdc

5.33 Amps

SPU80-107 18vdc 4.44 Amps
SPU80-108 24vdc 3.33 Amps
SPU80-109 30vdc 2.66 Amps
SPU80-110 36vdc 2.22 Amps
SPU80-111 48vdc 1.66 Amps

SPU80 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

Low Line 15Amps (115VAC) max High Line 30Amps (230VAC) max (@FL) cold start.

Power Factor Correction 0.97, typ.

Input Current

Low Line 1.0Amps max @ 115VAC/High Line 0.5Amps max @ 230VAC

Leakage Current

0.75 mAmps max.

General Specifications

Input-Out Isolation

3000 VAC

Input-Ground Isolation

1500 VAC

Isolation Resistance

50 MΩ min.

Efficiency

83%, typ.

Safety Approvals

(c)UL60950-1, EN60950-1

Physical Specifications

Size (mm)

146.0 x 42.93 x 76.2mm

Size (Inches)

5.75” x1.69” x 3.0”

Weight (g)

700g

Weight (oz)

1.54 oz

Output Specifications

Output Voltage

See Selection Chart Above

Output Amps

See Selection Chart Above

Load Regulation

±7%, max.

Line Regulation

± 1% Max.

Temperature Coefficient

±0.04%/°C, typ.

Ripple and Noise

FL, 90Vin; 1% Pk-Pk

Over Voltage Protection

112~132%

Over Current Protection

110~150%

Start Up, Hold Up Time

100Vin, FL; 2S max. /16mS min.

Environmental Specifications

Operating Temperature

0 to +40°C (FL); 50% Load @ 70°C

Storage Temperature

-40 to +85°C

Relative Humidity

5% to 95%, non-cond

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Low cost 3 Wire IEC320/C13 (Part Number ACCRD-C13) Input Power Cords are available for these products. Inquire with Astrodyne's Sales Department.

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.