Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU63 63w Switch Mode Power Supplies

SPU63 63w  Switch Mode Power Supplies

63W Desktop Switching Power Supplies

90-264VAC Input

IEC-320-C14 Input Receptacle

CEC and Energy Star Compliance

3000V Isolation

Splash Proof Case

Model Number

Output Voltage

Output Amps

Total Regulation

SPU63-105

12V

4.75A

5%

SPU63-106

15V

4.2A

5%

SPU63-107

18V

3.5A

5%

SPU63-108

24V

2.62A

5%

SPU63-109

30V

2.1A

5%

SPU63-110

36V

1.75A

3%

SPU63-111

48V

1.31A

3%

SPU63 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

Low Line (115VAC) 15A max./High Line (230VAC) 30A max. (cold start) typ.

Input Current

Low Line (115VAC) 1.6A/High Line (230VAC) 0.7A

Leakage Current

.075mA, max.

General Specifications

Isolation

3000 VAC

Isolation Input-Ground

1500VAC

Insulation Resistance

50 Mohm min.

Efficiency

88% FL,230Vin, typ

Safety Approvals

(c)UL60950-1, EN60950-1

Physical Specifications

Size (Inches)

4.65” x 1.34” x 2.05”

Construction

Desktop Style

Weight (g)

340g

Weight (oz)

12oz

Environmental Specifications

Notes

Output Specifications

Operating Temperature

0 to +40°C (FL)/50% Load @ 70°C (See Derate Curve)

EMC

110Vin: FCC Part 15 Class B/220Vin: CISPR-22 Class B

Storage Temperature

-40 to +85°C

Working Humidity

5% to 95%, non-cond

MTBF

130,000 Hrs/MIL-HDBK-217F

NOTE: Low cost 3 Wire IEC320/C13 (Part Number ACCRD-C13) Input Power Cords are available for these products. Inquire to the Astrodyne Sales Depart.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

12V

Output Amps

4.75A

Load Regulation

± 5%, max. 230Vin

Line Regulation

± 1%, max.

Total Regulation

5%

Temperature Coefficient

±0.04%/°C, typ

Ripple and Noise

FL, 240Vin 1% Pk-Pk, max.

Over Voltage Protection

112-132%

Over Current Protection

102-150%

Transient Response

100Vin, FL to 1/2L 4mS

Start Up, Rise Time

100Vin, FL 2S max.

Hold Up Time

100Vin, FL 16mS min.