Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU46 46 Watt Switch Mode Power Supplies

46 Watt Desktop Switching Power Supplies

Wide Input Voltage 90 to 264 VAC, 47 to 63 Hz

IEC-320-C14 Input Inlet

Splash proof

Single Output

Class I

Output Voltage Available from 5Volts(DC) thru 48Volts(DC)

Model Number

Output Voltage

Output Amps

SPU46-102

5vdc

8.0 Amps

SPU46-103

6vdc

7.5 Amps

SPU46-104

9vdc

5.0 Amps

SPU46-105

12vdc

3.75 Amps

SPU46-106

15vdc

3.0 Amps

SPU46-107

18vdc

2.77 Amps

SPU46-108

24vdc

2.08 Amps

SPU46-109

30vdc

1.66 Amps

SPU46-110

36vdc

1.38 Amps

SPU46-111

48vdc

1.04 Amps

SPU46 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

Low Line 15Amps max High Line 30Amps max

Input Current

Low Line 1.35Amps @ 115VAC/High Line 0.8Amps @ 230VAC

Leakage Current

0.75 mAmps max. @ 240VAC

General Specifications

Isolation

4242vdc Inpout-Output

Isolation Input-Ground

2121vdc Input-Ground

Insulation Resistance

50 M? / 500Volts(DC)

Efficiency

83% typ.@ FL @ 230Vin

Safety Approvals

(c)UL60950, EN60950-1

Physical Specifications

Size (mm)

146.0 x 76.0 x 43.0 mm

Size (Inches)

5.75” x 2.99” x 1.69”

Weight (g)

535~560g

Weight (oz)

18.87~19.75 oz

Output Specifications

Output Voltage

5vdc

Output Amps

8.0 Amps

Load Regulation

± 15%, max. @ 230VAC

Line Regulation

± 1%, max.

Temperature Coefficient

±0.04%/°C

Ripple and Noise

1% Pk-Pk @ 90VAC max

Over Voltage Protection

112~132%

Over Current Protection

110~150%

Transient Response

4mS @ 100VAC

Start Up, Rise Time

2S max @ 100VAC

Hold Up Time

16mS max @ 110VAC

Environmental Specifications

Operating Temperature

0 to +70°C

Storage Temperature

-40 to +85°C

Working Humidity

5% to 95%, non-cond

EMI

CISPR-22 Class B @ 220VAC FCC PART-15 Class B @ 110VAC

MTBF

0.1 MHrs MIL-HDBK-217F(25°C)

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.