Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU30 30w Switch Mode Power Supplies

30W Desktop Switching Power Supplies

Universal 90-264VAC Input

IEC-320-C14 Input Receptacle

Single Outputs from 3.3 to 48VDC

3000V Isolation

Splash Proof Case

Model Number

Output Voltage

Output Amps

Total Regulation

SPU30-101

3.3V

5A

7%

SPU30-102

5V

5A

5%

SPU30-103

6V

4.16A

5%

SPU30-104

10V

3A

5%

SPU30-105

12V

2.5A

5%

SPU30-106

15V

2A

5%

SPU30-107

18V

1.6A

5%

SPU30-108

24V

1.25A

5%

SPU30-109

30V

1A

5%

SPU30-110

36V

0.83A

3%

SPU30-111

48V

0.62A

3%

SPU30 series

Input Specifications

Input Voltage Range

90-264 VAC (Universal)

Frequency Range

47-63 Hz

Inrush Current

Low Line (115VAC) 15A max./High Line (230VAC) 30A max. (cold start) typ.

Input Current

Low Line (115VAC) 0.8A/High Line (230VAC) 0.5A

Leakage Current

0.75mA MAX. @ 240 VAC, FL

General Specifications

Isolation

3000 VAC

Isolation Input-Ground

1500VAC

Insulation Resistance

50 Mohm min.

Efficiency

75%, typ FL, 230 Vin

Safety Approvals

(c)UL60950-1

Physical Specifications

Size (Inches)

4.6” x 1.36” x 2.0”

Construction

Desktop Style

Weight (g)

230g

Weight (oz)

8.1oz

Output Specifications

Output Voltage

3.3V

Output Amps

5A

Load Regulation

± 7%, max. 230Vin

Line Regulation

± 1%, max. ±0.5% typ.

Total Regulation

7%

Temperature Coefficient

±0.04%/°C, typ

Ripple and Noise

FL, 90Vin 2% Pk-Pk, max.

Over Voltage Protection

112-132%

Over Current Protection

110-150%

Transient Response

100Vin, FL to 1/2L 4mS

Start Up, Rise Time

100Vin, FL 2S max.

Hold Up Time

100Vin, FL 12mS min.

Environmental Specifications

Operating Temperature

0 to +40°C (FL) 50% Load @ 70°C (See Derate Curve)

EMC

110Vin: FCC Part 15 Class B/220Vin: CISPR-22 Class B

Storage Temperature

-40 to +85°C

Working Humidity

5% to 95%, non-cond

MTBF

100,000 Hrs

Notes

NOTE: Low cost 3 Wire IEC320/C13 (Part Number ACCRD-C13) Input Power Cords are available for these products. Inquire to the Astrodyne Sales Depart.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.