Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU16 16w 16 Watt Switch Mode Power Supplies

SPU16 16w 16 Watt  Switch Mode Power Supplies

15 Watt Desktop Switching Power Adapters

Universal 90-264VAC Input

3 Input Connection Options

Single Outputs from 3.3 to 48VDC

3000V Isolation

Splash Proof Case

LPS, CEC and Energy Star Approvals

Model Number

Output Voltage

Output Amps

Total Regulation

SPU16A-101

SPU16B-101

SPU16D-101

3.3V

2.5A

7%

SPU16A-102

SPU16B-102

SPU16D-102

5V

2.4A

5%

SPU16A-103

SPU16B-103

SPU16D-103

6V

2.0A

5%

SPU16A-104

SPU16B-104

SPU16D-104

10V

1.5A

5%

SPU16A-105

SPU16B-105

SPU16D-105

12V

1.25A

5%

SPU16A-106

SPU16B-106

SPU16D-106

15V

1.0A

5%

SPU16A-107

SPU16B-107

SPU16D-107

18V

0.83A

5%

SPU16A-108

SPU16B-108

SPU16D-108

24V

0.62A

5%

SPU16A-109

SPU16B-109

SPU16D-109

30V

0.5A

5%

SPU16A-110

SPU16B-110

SPU16D-110

36V

0.41A

3%

SPU16A-111

SPU16B-111

SPU16D-111

48V

0.31A

3%

Note: A, B, or D Option denotes a choice of AC input connectors. Please see Mechanical Dimensions. If not denoted, option A (IEC-320-C14) connector is used.

SPU16A/B/D series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

Low Line (115VAC) 15A max./High Line (230VAC) 30A max. (cold start) typ.

Input Current

Low Line (115VAC) 0.4A/High Line (230VAC) 0.26A

Leakage Current

0.75mA MAX. @ 240 VAC, FL

General Specifications

Isolation

I/P - O/P: 3000 VAC

Isolation Input-Ground

I/P - GND: 1500 VAC

Insulation Resistance

50 M? min.

Efficiency

80%, min. FL, 230Vin

Switching Frequency

89 KHz

Safety Approvals

(c)UL60950-1, EN60950-1

Physical Specifications

Size (Inches)

3.58” x 1.5” x 1.42”

Construction

Desktop Style

Weight (g)

165g

Weight (oz)

5.8oz

Output Specifications

Output Voltage

3.3V

Output Amps

2.5A

Load Regulation

± 3%, typ. 230 Vin

Line Regulation

± 1%, max.

Total Regulation

7%

Temperature Coefficient

±0.04%/°C, typ

Ripple and Noise

1% Pk-Pk max. (2%, 3.3Vout) FL, 90Vin

Transient Response

100Vin, FL to 1/2L 4mS

Short Circuit Protection

Continuous, self-recovering

Start Up, Rise Time

100Vin, FL 2S max.

Hold Up Time

100Vin, FL 5 mS min.

Environmental Specifications

Operating Temperature

0 to +40°C (FL)/50% Load @ 70°C (See Derate Curve)

EMC

110Vin: FCC Part 15 Class B/220Vin: CISPR-22 Class B

Storage Temperature

-40 to +85°C

Working Humidity

5% to 95%, non-cond

MTBF

100,000 Hrs

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.