Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU130 130w Switch Mode Power Supplies

130 Watt Desktop Switching Power Adapters

Universal 85-265VAC Input

3.3 to 48 VDC Outputs

Regulated, Single & Dual Outputs

3000V Isolation

IEC320-C14 Input Inlet

Model Number

Min. Load

Output Voltage

Output Amps

Load Regulation

SPU130-101(M)

0A

3.3

27.27

7%

SPU130-102(M)

0A

5

23

7%

SPU130-103(M)

0A

6

21.6

5%

SPU130-104(M)

0A

10

13

5%

SPU130-105(M)

0A

12

10.8

5%

SPU130-106(M)

0A

15

8.66

5%

SPU130-107(M)

0A

18

7.22

5%

SPU130-108(M)

0A

24

5.41

5%

SPU130-109(M)

0A

30

4.33

3%

SPU130-110(M)

0A

36

3.61

3%

SPU130-111(M)

0A

48

2.7

3%

SPU130-200(M)

4/0A

3.3/12

20/2 max.

7/5% max.

SPU130-201(M)

4/0A

5/12

20/2 max.

7/5% max.

SPU130-202(M)

4/0A

5/15

20/2 max.

7/5% max.

SPU130-203(M)

4/0A

5/24

20/2 max.

7/5% max.

SPU130 series

Input Specifications

Input Voltage Range

85-265VAC

Frequency Range

47-63 Hz

Inrush Current

Low Line 30A max., 15A typ. / High Line 60A max., 30A typ.

Input Current

Low Line 3.2A / High Line 1.7A

Leakage Current

0.5-0.75mA

Power Factor Correction

0.95 min. 0.99 max.

Min. Load

0A

General Specifications

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Insulation Resistance

50 Mohm

Efficiency

80-85% typ.

Switching Frequency

54.5 KHz

Safety Approvals

cUL60950-1, EN60950

Physical Specifications

Size (Inches)

7.7”x3.46”x2.0”

Construction

Desktop Style

Weight (g)

860g

Weight (oz)

30.33

Output Specifications

Environmental Specifications

Operating Temperature

0 to +70°C w. Derate See Curve

EMC

Vin = 220VAC CISPR-22 B / Vin = 110VAC FCC Part 15B

Storage Temperature

-40 to +85°C

Working Humidity

5 to + 95%, non-cond

MTBF

100,000 Hrs

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

3.3

Output Amps

27.27

Load Regulation

7%

Line Regulation

± 1%, max. ± 0.5% typ. (@ FL)

Temperature Coefficient

±0.04%/°C, typ

Ripple and Noise

1% Pk-Pk, typ (2% Max.)

Over Voltage Protection

112-132% (O/P 1 only)

Over Current Protection

110-150% of Rated Current

Transient Response

4mS 50%-100% Load

Start Up, Rise Time

0.3/1/2 Seconds

Hold Up Time

75-85mS at 110VAC Input