Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SPU10 10w Switch Mode Power Supplies

10 Watt Wallmount Switching Power Supplies

Wide Input Voltage 90 to 264 VAC, 47 to 63 Hz

2 Prong Plug-in Mains Connector

Output Voltage Available from 5Volts(DC) thru 36Volts(DC)

Single Output

Class II

Energy Star Compliance

Model Number

Output Voltage

Output Amps

SPU10-102

5 Volts(DC)

1.60 Amps

SPU10-103

6 Volts(DC)

1.33 Amps

SPU10-104

9 Volts(DC)

1.11 Amps

SPU10-105

12 Volts(DC)

0.83 Amps

SPU10-106

15 Volts(DC)

0.66 Amps

SPU10-107

18 Volts(DC)

0.55 Amps

SPU10-108

24 Volts(DC)

0.42 Amps

SPU10-109

30 Volts(DC)

0.33 Amps

SPU10-110

36 Volts(DC)

0.28 Amps

SPU10 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

@ FL (Cold Start) Low Line 30Amps maxAmps typ. High Line 60Amps max @ 230VAC

Input Current

@ FL Low Line 0.3Amps @ 115VAC High Line 0.2Amps @ 230VAC

Leakage Current

@ FL 0.25 mAmps max. @ 240VAC

General Specifications

Isolation

4242 Volts(DC)

Efficiency

@ FL @230VAC 75% min. / 80% typ. / 85% max

Physical Specifications

Size (mm)

56.0 x 44.0 x 27.5 mm

Size (Inches)

2.2” x 1.73” x 1.08”

Weight (g)

90g

Weight (oz)

3.17oz

Output Specifications

Output Voltage

5 Volts(DC)

Output Amps

1.60 Amps

Load Regulation

@ FL ± 5%, max. @ 230VAC

Temperature Coefficient

±0.04%/°C

Ripple and Noise

@ FL 1% Pk-Pk @ 90VAC max. 0.5% Pk-Pk @ 90VAC typ.

Transient Response

4mS @ 100VAC

Short Circuit Protection

Continuous

Start Up, Rise Time

1S typ.

Hold Up Time

10mS typ. @ 100VAC @ FL

Environmental Specifications

Operating Temperature

0 to +70°C (FL)

Working Humidity

5% to 95%, non-cond

EMI

CISPR-22 Class B @ 220VAC FCC PART-15 Class B @ 110VAC

MTBF

0.1 MHrs MIL-HDBK-217F(25°C)

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.