Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SP750 750 Watt Enclosed Power Supplies

750W Single Output with PFC Function

Universal AC input

Protections:Short circuit/Over load/Over voltage/Over temperature

Built-in active PFC function, PF>0.96

Forced air cooling by built-in DC ball bearing fan

High power density of 5.48W/cubic inch

Built-in remote ON-OFF control

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

SP750-5 5vdc 120 Amps

±2.0%

±0.5%

5.75 ~ 6.75Volt(DC) Shutdown o/p voltage, re-power

4.75~5.5Volt(DC)

0.8

SP750-12 12vdc 62.5 Amps

±0.5%

±0.3%

13.8 ~ 16.2Volt(DC) Shutdown o/p voltage, re-power

10~13.5Volt(DC)

0.85

SP750-15 15vdc 50 Amps

±0.5%

±0.3%

18 ~ 21Volt(DC) Shutdown o/p voltage, re-power

13.5~16.5Volt(DC)

0.87

SP750-24 24vdc 31.3 Amps

±0.5%

±2.0%

27.6 ~ 32.4Volt(DC) Shutdown o/p voltage, re-power

22~26.4Volt(DC)

0.89

SP750-27 27vdc 27.8 Amps

±0.5%

±2.0%

31 ~ 36.5Volt(DC) Shutdown o/p voltage, re-power

24~30Volt(DC)

0.89

SP750-48 48vdc 15.7 Amps

±0.5%

±2.0%

57.6~ 67.2Volt(DC) Shutdown o/p voltage, re-power

43~56Volt(DC)

0.9

SP750 series

Input Specifications

Input Voltage Range

90 ~ 264VAC 127~370vdc

Input Reflected Ripple Current

8.8Amps @ 115VAC, 4.2 Amps @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

27Amps/115VAC; 45Amps 230VAC (cold start)

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

80%

Switching Frequency

UL60950-1, TUV EN60950-1 Approved

Operating Temperature

-20°C to +60°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

MTBF

124KHrs min,MIL-HDBK-217F(25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, ENV55024, EN61000-6-2 EN61204-3 heavy Industry Level, Criteria A

Environmental Specifications

Output Specifications

Output Voltage

5vdc

Output Amps

120 Amps

Load Regulation

±2.0%

Line Regulation

±0.5%

Temperature Coefficient

0.05% / °C (0-50°C)

Ripple and Noise

120mVpk-pk max (Note 1)

Over Voltage Protection

5.75 ~ 6.75Volt(DC) Shutdown o/p voltage, re-power

Over Current Protection

105~135% rated output power Constant current limiting, unit will Hiccup after 3sec

Over Temperature Protection

85°C ±5°C (TSW1) detect on heatsink of power transitor 85°C ±5°C (TSW2) detect on heasink of power diode Shutdown o/p volt, auto recover after cool down

DC Voltage Adjust (typ.)

4.75~5.5Volt(DC)

Hold Up Time

16mS /230VAC, 16mS /115VAC

Remore Shutdown

RC+/RC-: short= Power on, Open= Power off (Note 3)

Physical Specifications

Size (mm)

278 x 127 x 63.5mm

Size (Inches)

10.94” x 5 ”x 2.5”

Weight (g)

2900g

Weight (oz)

102.29oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.