200W Single Output with PFC Function
SP200DRL 200w Power Supplies
|
Universal AC input/full range |
|
|
Built-in active PFC function, PF>0.93 |
|
|
Protections: Short circuit/Over Load/Over voltage/Over Temperature |
|
|
Built-in cooling fan speed control |
|
|
Built-in constant current limiting circuit |
|
|
Built-in fan speed control |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
3.3V |
40A |
+/-1% |
100mVp-p max. (Note 2) |
3.63~4.46V Shut down o/p voltage, re-power on to recover |
+/-2% (Note 3) |
3.14~ 3.63V |
0~40A |
65% typ. |
|
|
5V |
40A |
+/-1% |
100mVp-p max. (Note 2) |
5.5~6.75V Shut down o/p voltage, re-power on to recover |
+/-2% (Note 3) |
4.75~ 5.5V |
0~40A |
71% typ. |
|
|
7.5V |
26.7A |
+/-1% |
100mVp-p max. (Note 2) |
8.25~10.13V Shut down o/p voltage, re-power on to recover |
+/-2% (Note 3) |
7.13~ 8.25V |
0~26.7A |
76% typ. |
|
|
12V |
16.7A |
+/-0.5% |
100mVp-p max. (Note 2) |
13.2~16.2V Shut down o/p voltage, re-power on to recover |
+/-2% (Note 3) |
11.4~ 13.2V |
0~16.7A |
79% typ. |
|
|
13.5V |
14.9A |
+/-0.5% |
100mVp-p max. (Note 2) |
14.85~18.2V Shut down o/p voltage, re-power on to recover |
+/-2% (Note 3) |
12.8~ 14.9V |
0~14.9A |
80% typ. |
|
|
15V |
13.4A |
+/-0.5% |
100mVp-p max. (Note 2) |
16.5~20.25V Shut down o/p voltage, re-power on to recover |
+/-2% (Note 3) |
14.3~ 16.5V |
0~13.4A |
81% typ. |
|
|
24V |
8.4A |
+/-0.5% |
150mVp-p max. (Note 2) |
26.4~32.4V Shut down o/p voltage, re-power on to recover |
+/-1% (Note 3) |
22.8~ 26.4V |
0~8.4A |
83% typ. |
|
|
27V |
7.5A |
+/-0.5% |
150mVp-p max. (Note 2) |
29.7~36.45V Shut down o/p voltage, re-power on to recover |
+/-1% (Note 3) |
25.7~ 29.7V |
0~7.5A |
83% typ. |
|
|
48V |
4.2A |
+/-0.5% |
250mVp-p max. (Note 2) |
52.8~64.8V Shut down o/p voltage, re-power on to recover |
+/-1% (Note 3) |
45.6~ 52.8V |
0~4.2A |
84% typ. |
SP200/DRL series
|
Input Specifications General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |