Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SP200DRL 200w Power Supplies

200W Single Output with PFC Function

Universal AC input/full range

Built-in active PFC function, PF>0.93

Protections: Short circuit/Over Load/Over voltage/Over Temperature

Built-in cooling fan speed control

Built-in constant current limiting circuit

Built-in fan speed control

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

SP200-3.3

3.3V

40A

+/-1%

100mVp-p max. (Note 2)

3.63~4.46V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

3.14~ 3.63V

0~40A

65% typ.

SP200-5

5V

40A

+/-1%

100mVp-p max. (Note 2)

5.5~6.75V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

4.75~ 5.5V

0~40A

71% typ.

SP200-7.5

7.5V

26.7A

+/-1%

100mVp-p max. (Note 2)

8.25~10.13V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

7.13~ 8.25V

0~26.7A

76% typ.

SP200-12

12V

16.7A

+/-0.5%

100mVp-p max. (Note 2)

13.2~16.2V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

11.4~ 13.2V

0~16.7A

79% typ.

SP200-13.5

13.5V

14.9A

+/-0.5%

100mVp-p max. (Note 2)

14.85~18.2V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

12.8~ 14.9V

0~14.9A

80% typ.

SP200-15

15V

13.4A

+/-0.5%

100mVp-p max. (Note 2)

16.5~20.25V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

14.3~ 16.5V

0~13.4A

81% typ.

SP200-24

24V

8.4A

+/-0.5%

150mVp-p max. (Note 2)

26.4~32.4V Shut down o/p voltage, re-power on to recover

+/-1% (Note 3)

22.8~ 26.4V

0~8.4A

83% typ.

SP200-27

27V

7.5A

+/-0.5%

150mVp-p max. (Note 2)

29.7~36.45V Shut down o/p voltage, re-power on to recover

+/-1% (Note 3)

25.7~ 29.7V

0~7.5A

83% typ.

SP200-48

48V

4.2A

+/-0.5%

250mVp-p max. (Note 2)

52.8~64.8V Shut down o/p voltage, re-power on to recover

+/-1% (Note 3)

45.6~ 52.8V

0~4.2A

84% typ.

SP200/DRL series

Input Specifications

General Specifications

Isolation

3KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

65% typ.

Safety Approvals

UL60950-1, TUV EN609050-1 and S-MARK J60950 Approved (Note 4)

Harmonic Current

Compliance to EN61000-3-2,-3 (Note 4)

Environmental Specifications

Input Voltage Range

85~264VAC 120~370VDC

Frequency Range

47~63Hz

Inrush Current

Cold Start 40A/230VAC typ.

Input Current

3.5A/115VAC 1.7A/230VAC typ.

Leakage Current

<2mA/240VAC

Power Factor Correction

PF>0.93/230VAC PF>0.98/115VAC at full load typ.

Operating Temperature

-10~+60°C (Refer to output load derating curve)

Storage Temperature

-20~+85°C

Working Humidity

20 ~ 90 % RH non-condensing

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN55022 (CISPR22) Class B (Note 4)

MTBF

183.8K hrs min. MI:-HDBK-217F (25°C)

Vibration

10~500Hz, 2G 10min./l Cycle, 60 min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024, Light Industry Level, criteria A (Note 4)

Size (mm)

199mm x 99mm x 50mm

Weight (g)

0.85Kg; 20pcs/17.9Kg/1.28CUFT

Output Specifications

Output Voltage

3.3V

Output Amps

40A

Load Regulation

±1%

Line Regulation

±0.5%

Temperature Coefficient

±0.05%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

3.63~4.46V Shut down o/p voltage, re-power on to recover

Over Current Protection

105 ~ 150% rated output power. Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Temperature Protection

95°C ±5°C (TSW1 : Detect on heatsink of power transistor). Protection type: shut down o/p voltage, recovers automatically after tempertature goes down

Voltage Tolerance

±2% (Note 3)

DC Voltage Adjust

3.14~3.63V

Minimum Load Requirement

0~40A

Rise Time

600ms, 30 ms at full load

Hold Up Time

20mS at full load typ.

Remote Shutdown

CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF (option)

Physical Specifications

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.