200W Single Output with PFC Function
SP200 200w Power Supplies
|
Universal AC input |
|
|
Protections:Short circuit/Over load/Over voltage/Over temperarure |
|
|
Built-in active PFC function, PF >0.93 |
|
|
Built-in cooling fan speed control |
|
|
Built-in constant current limiting circuit |
|
|
Remote ON-OFF control(optional) |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
3.3 Volts(DC) |
40 Amps |
±1.0% |
100mVpk-pk (Note 1) |
3.63 ~ 4.46Volt(DC) Shut down o/p voltage, re-power |
3.14~3.63Volt(DC) |
0.65 |
|
|
5 Volts(DC) |
40 Amps |
±1.0% |
100mVpk-pk (Note 1) |
5.5 ~ 6.75Volt(DC) Shut down o/p voltage,re-power |
4.75~5.5Volt(DC) |
0.71 |
|
|
7.5 Volts(DC) |
26.7 Amps |
±1.0% |
100mVpk-pk (Note 1) |
8.25 ~ 10.13Volt(DC) Shut down o/p voltage,re-power |
7.13~8.25Volt(DC) |
0.76 |
|
|
12 Volts(DC) |
16.7 Amps |
±0.5% |
100mVpk-pk (Note 1) |
13.2 ~ 16.2Volt(DC) Shut down o/p voltage,re-power |
11.4~13.2Volt(DC) |
0.79 |
|
|
13.5 Volts(DC) |
14.9 Amps |
±0.5% |
100mVpk-pk (Note 1) |
14.85 ~ 18.2Volt(DC) Shut down o/p voltage, re-power |
12.8~14.9Volt(DC) |
0.8 |
|
|
15 Volts(DC) |
13.4 Amps |
±0.5% |
100mVpk-pk (Note 1) |
16.5 ~ 20.25Volt(DC) Shut down o/p voltage,re-power |
14.3~16.5Volt(DC) |
0.81 |
|
|
24 Volts(DC) |
8.4 Amps |
±0.5% |
150mV pk-pk (Note 1) |
26.4 ~ 32.4Volt(DC) Shut down o/p voltage,re-power |
22.8~26.4Volt(DC) |
0.83 |
|
|
27 Volts(DC) |
7.5 Amps |
±0.5% |
150mV pk-pk (Note 1) |
29.7 ~ 36.45Volt(DC) Shut down o/p voltage,re-power |
25.7~29.7Volt(DC) |
0.83 |
|
|
48 Volts(DC) |
4.2 Amps |
±0.5% |
250mV pk-pk (Note 1) |
52.8 ~ 64.8Volt(DC) Shut down o/p voltage,re-power |
45.6~52.8Volt(DC) |
0.84 |
SP200 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications Notes
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |