Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SP150DRL 150w Power Supplies

150W Single Output with PFC Function

Universal AC input/full range

Built-in active PFC Function, PF>0,93

Protections: Short circuit/Over Load/Over voltage/Over Temperature

Built-in constant current limiting circuit

Remote ON-OFF control (optional)

LED indicator for power on

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

SP150-3.3

3.3V

30A

+/-1%

100mVp-p max. (Note 2)

3.63~4.46V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

3.14~3.63V

0~30A

67% typ.

SP150-5

5V

30A

+/-1%

100mVp-p max. (Note 2)

5.5~6.75V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

4.75~5.5V

0~30A

75% typ.

SP150-7.5

7.5V

20A

+/-1%

100mVp-p max. (Note 2)

8.25~10.13V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

7.13~8.25V

0~20A

79% typ.

SP150-12

12V

12.5A

+/-0.5%

100mVp-p max. (Note 2)

13.2~16.2V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

11.4~13.2V

0~12.5A

80% typ.

SP150-13.5

13.5V

11.2A

+/-0.5%

100mVp-p max. (Note 2)

14.85~18.2V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

12.8~14.9V

0~11.2A

80% typ.

SP150-15

15V

10A

+/-0.5%

100mVp-p max. (Note 2)

16.5~20.25V Shut down o/p voltage, re-power on to recover

+/-2% (Note 3)

14.3~16.5V

0~10A

81% typ.

SP150-24

24V

6.3A

+/-0.5%

150mVp-p max. (Note 2)

26.4~32.4V Shut down o/p voltage, re-power on to recover

+/-1% (Note 3)

22.8~26.4V

0~6.3A

83% typ.

SP150-27

27V

5.6A

+/-0.5%

150mVp-p max. (Note 2)

29.7~36.45V Shut down o/p voltage, re-power on to recover

+/-1% (Note 3)

25.7~29.7V

0~5.6A

84% typ.

SP150-48

48V

3.2A

+/-0.5%

250mVp-p max. (Note 2)

52.8~62.8V Shut down o/p voltage, re-power on to recover

+/-1% (Note 3)

45.6~52.8V

0~3.2A

84% typ.

SP150/DRL series

General Specifications

Isolation

3KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

67% typ.

Safety Approvals

UL60950-1, TUV EN609050-1 and S-MARK J609050 Approved (Note 4)

Harmonic Current

Compliance to EN61000-3-2,-3 (Note 4)

Environmental Specifications

Operating Temperature

-10~+60°C (Refer to output load derating curve)

Storage Temperature

-20~+85°C

Working Humidity

20 ~ 90 % RH non-condensing

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN55022 (CISPR22) Class B (Note 4)

MTBF

191.2K Hrs min. MIL-HDBK-217F (25°C)

Vibration

10~500Hz, 2G 10min./l Cycle, 60 min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024, Light Industry Level, criteria A (Note 4)

Input Voltage Range

85~264VAC 120-370VDC (Note 5)

Frequency Range

47~63Hz

Inrush Current

Cold Start 40A/230VAC typ.

Input Current

2.5A/115VAC 1.2A/230VAC typ.

Leakage Current

<2mA/240VAC

Power Factor Correction

PF>0.93/230VAC PF0.98/115VAC at Full Load typ.

Input Specifications

Output Specifications

Output Voltage

3.3V

Output Amps

30A

Load Regulation

±1%

Line Regulation

±0.5%

Temperature Coefficient

±0.05%/°C 90~50°C

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

3.63~4.46V Shut down o/p voltage, re-power on to recover

Over Current Protection

105 ~ 135% rated output power, Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Temperature Protection

95°C ±5°C (TSW1 : Detect on heatsink of power transistor). Protection type: shut down o/p voltage, recovers automatically after tempertature goes down

Voltage Tolerance

±2% (Note 3)

DC Voltage Adjust

3.14~3.63V

Minimum Load Requirement

0~30A

Rise Time

600ms, 30ms at full load

Hold Up Time

20mS at full load typ.

Remote Shutdown

CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF (option)

Physical Specifications

Size (mm)

199mm x 99mm x 50mm

Weight (g)

0.76Kg; 20pcs/16.4Kg/1.28CUFT

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

5. Derating may be needed under low input voltages. Plese check the derating curve for more details.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.