100W Single Output with PFC Function
SP100DRL 100w Power Supplies
|
Universal AC input / full range |
|
|
Built-in active PFC function, PF.0.93 |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
Built-in constant current limiting circuit |
|
|
Remote ON-OFF control (optional) |
|
|
LED indicator for power on |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
3.3V |
30A |
±1% |
100mVpk-pk (Note 2) |
3.63~4.46V Shut down o/p voltage, re-power on to recover |
3.14~3.63V |
0~20A |
70% typ. |
|
|
5V |
20A |
±1% |
100mVpk-pk (Note 2) |
5.5~6.75V Shut down o/p voltage, re-power on to recover |
4.75~5.5V |
0~20A |
76% typ. |
|
|
7.5V |
13.5A |
±1% |
100mVpk-pk (Note 2) |
8.25~10.13V Shut down o/p voltage, re-power on to recover |
7.13~8.25V |
0~13.5A |
78% typ. |
|
|
12V |
8.5A |
±0.5% |
100mVpk-pk (Note 2) |
13.2~16.2V Shut down o/p voltage, re-power on to recover |
11.4~13.2V |
0~8.5A |
80% typ. |
|
|
13.5V |
7.5A |
±0.5% |
100mVpk-pk (Note 2) |
14.85~18.23V Shut down o/p voltage, re-power on to recover |
12.8~14.9V |
0~7.5A |
80% typ. |
|
|
15V |
6.7A |
±0.5% |
100mVpk-pk (Note 2) |
16.5~20.25V Shut down o/p voltage, re-power on to recover |
14.3~16.5V |
0~6.7A |
82% typ. |
|
|
24V |
4.2A |
±0.5% |
150mVpk-pk (Note 2) |
26.4~32.4V Shut down o/p voltage, re-power on to recover |
22.8~26.4V |
0~4.2A |
84% typ. |
|
|
27V |
3.8A |
±0.5% |
150mVpk-pk (Note 2) |
29.7~36.45V Shut down o/p voltage, re-power on to recover |
25.7~29.7V |
0~3.8A |
83% typ. |
|
|
48V |
2.1A |
±0.5% |
250mVpk-pk (Note 2) |
52.8~64.8V Shut down o/p voltage, re-power on to recover |
45.6~52.8V |
0~2.1A |
82% typ. |
SP100DRL series
|
Input Specifications General Specifications
Environmental Specifications
|
Physical Specifications 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. Output Specifications
Notes
|