Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SD50DRL 50 Watt DIN Rail Mount Converters

50W Single Output DC-DC Converter

2.1 wide input range

Protections: Short circuit/Over load/Over voltage

1500VDC I/O isolation

Built-in EMI filter, low ripple noise

100% full load burn-in test

Fixed switching frequency at 83KHz, low cost, High reliability

Model Number

Input Voltage Range

Input Current

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

SD50A-5/DRL 9.2~18VDC 7A/12V

5V

10A

+/- 0.5%

+/- 0.5%

100mVp-p max. (Note 2)

SD50B-5/DRL 19~36VDC 7A/12V

5V

10A

+/- 0.5%

+/- 0.5%

100mVp-p max. (Note 2)

SD50C-5/DRL 36~72VDC 7A/12V

5V

10A

+/- 0.5%

+/- 0.5%

100mVp-p max. (Note 2)

SD50A-12/DRL 9.2~18VDC 3A/24V

12V

4.2A

+/-0.3%

+/-0.3%

120mVp-p max. (Note 2)

SD50B-12/DRL 19~36VDC 3A/24V

12V

4.2A

+/-0.3%

+/-0.3%

120mVp-p max. (Note 2)

SD50C-12/DRL 36~72VDC 3A/24V

12V

4.2A

+/-0.3%

+/-0.3%

120mVp-p max. (Note 2)

SD50A-24/DRL

9.2~18VDC

1.5A/48V

24V

2.1A

+/-0.2%

+/-0.2%

150mVp-p max. (Note 2)

SD50B-24/DRL 19~36VDC 1.5A/48V

24V

2.1A

+/-0.2%

+/-0.2%

150mVp-p max. (Note 2)

SD50C-24/DRL

36~72VDC

1.5A/48V

24V

2.1A

+/-0.2%

+/-0.2%

150mVp-p max. (Note 2)

Model Number

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

MTBF

Efficiency

SD50A-5/DRL

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 2.0% (Note 3)

4.5 ~ 5.5VDC

0~10A

365.6K hrs min. MIL-HDBK-217F (25°C)

70% typ.

SD50B-5/DRL

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 2.0% (Note 3)

4.5 ~ 5.5VDC

0~10A

365.6K hrs min. MIL-HDBK-217F (25°C)

73% typ.

SD50C-5/DRL

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 2.0% (Note 3)

4.5 ~ 5.5VDC

0~10A

365.6K hrs min. MIL-HDBK-217F (25°C)

76% typ.

SD50A-12/DRL

16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

11~ 16VDC

0~4.2A

357.5K hrs min. MIL-HDBK-217F (25°C)

72% typ.

SD50B-12/DRL

16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

11~ 16VDC

0~4.2A

357.5K hrs min. MIL-HDBK-217F (25°C)

75% typ.

SD50C-12/DRL

16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

11~ 16VDC

0~4.2A

357.5K hrs min. MIL-HDBK-217F (25°C)

78% typ.

SD50A-24/DRL

31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

23~ 30VDC

0~2.1A

368.5K hrs min. MIL-HDBK-217F (25°C)

74% typ.

SD50B-24/DRL

31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

23~ 30VDC

0~2.1A

368.5K hrs min. MIL-HDBK-217F (25°C)

80% typ.

SD50C-24/DRL

31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

+/- 1.0% (Note 3)

23~ 30VDC

0~2.1A

368.5K hrs min. MIL-HDBK-217F (25°C)

83% typ.

SD50/DRL series

Input Specifications

General Specifications

Operating Temperature

-10°C to +60°C (Refer to output load derating curve)

Storage Temperature

-20°C to +85°C

Working Humidity

20 to +90% RH non cond

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN 55022 (CISPR22) Class B (Note 4)

MTBF

365.6K hrs min. MIL-HDBK-217F (25°C)

Vibration

10 ~ 500Hz. 2G 10- min./1 cycle, 60min. Each along X, Y, Z axes

EMS

Compliance to EN61000-4-2,3,4,5,6,8; ENV50204, EN55024, heavy industry level, criteria A (Note 4)

Input Voltage Range

9.2~18VDC

Input Current

7A/12V

Isolation

1.5KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

70% typ.

Safety Approvals

Design refer to LVD (Note 4)

Environmental Specifications

Output Specifications

Physical Specifications

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted.

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

5V

Output Amps

10A

Load Regulation

± 0.5%

Line Regulation

± 0.5%

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over Current Protection

105 ~ 150% rated output power, Protection type: fold back current limiting, recovers automatically after fault condition is removed

Voltage Tolerance

± 2.0% (Note 3)

DC Voltage Adjust

4.5 ~ 5.5VDC

Minimum Load Requirement

0~10A

Rise Time

2.5s, 50ms at full load

Size (mm)

159x97x38

Weight (g)

0.53Kg; 24pcs/12.7Kg/0.75CUFT