Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SD50 50 Watt Enclosed Converters

50W Single Output DC-DC Converter

2:1 wide input range

Protections: Short circuit/Over load/Over voltage

1500VDC I/O isolation

Built-in EMI filter, low ripple noise

100% full load burn-in test

Fixed switching frequency at 83KHz

Model Number

Input Voltage Range

DC Current

Minimum Load Requirement

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

SD50A-5 9.2~18VDC 7A/12V

0~10A

5V

10A

±0.5%

±0.5%

100mVp-p max. (Note 2)

SD50B-5 19~36VDC 7A/12V

0~10A

5V

10A

±0.5%

±0.5%

100mVp-p max. (Note 2)

SD50C-5 36~72VDC 7A/12V

0~10A

5V

10A

±0.5%

±0.5%

100mVp-p max. (Note 2)

SD50A-12 9.2~18VDC 3A/24V

0~4.2A

12V

4.2A

±0.3%

±0.3%

120mVp-p max. (Note 2)

SD50B-12 19~36VDC 3A/24V

0~4.2A

12V

4.2A

±0.3%

±0.3%

120mVp-p max. (Note 2)

SD50C-12 36~72VDC 3A/24V

0~4.2A

12V

4.2A

±0.3%

±0.3%

120mVp-p max. (Note 2)

SD50A-24 9.2~18VDC 1.5A/48V

0~2.1

24V

2.1A

±0.2%

±0.2%

150mVp-p max. (Note 2)

SD50B-24 19~36VDC 1.5A/48V

0~2.1

24V

2.1A

±0.2%

±0.2%

150mVp-p max. (Note 2)

SD50C-24 36~72VDC 1.5A/48V

0~2.1

24V

2.1A

±0.2%

±0.2%

150mVp-p max. (Note 2)

Model Number

Voltage Tolerance

Over Voltage Protection

DC Voltage Adjust (typ.)

MTBF

Efficiency

SD50A-5

±2% (Note 3)

5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

4.5~5.5VDC

365.6K hrs min. MIL-HDBK-217F (25°C)

70% typ.

SD50B-5

±2% (Note 3)

5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

4.5~5.5VDC

357.5K hrs min. MIL-HDBK-217F (25°C)

73% typ.

SD50C-5

±2% (Note 3)

5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

4.5~5.5VDC

368.5K hrs min. MIL-HDBK-217F (25°C)

76% typ.

SD50A-12

±1% (Note 3)

16.8~20V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

11~16VDC

365.6K hrs min. MIL-HDBK-217F (25°C)

72% typ.

SD50B-12

±1% (Note 3)

16.8~20V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

11~16VDC

357.5K hrs min. MIL-HDBK-217F (25°C)

75% typ.

SD50C-12

±1% (Note 3)

16.8~20V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

11~16VDC

368.5K hrs min. MIL-HDBK-217F (25°C)

78% typ.

SD50A-24

±1% (Note 3)

31.5~37.5V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

23~30VDC

365.6K hrs min. MIL-HDBK-217F (25°C)

74% typ.

SD50B-24

±1% (Note 3)

31.5~37.5V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

23~30VDC

357.5K hrs min. MIL-HDBK-217F (25°C)

80% typ.

SD50C-24

±1% (Note 3)

31.5~37.5V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

23~30VDC

368.5K hrs min. MIL-HDBK-217F (25°C)

83% typ.

SD50 series

Input Specifications

Input Voltage Range

9.2~18VDC

DC Current

7A/12V

Minimum Load Requirement

0~10A

General Specifications

Isolation

1.5KVAC

Isolation Input-Ground

1.5KVAC

Isolation Output-Ground

0.5KVAC

Insulation Resistance

100M Ohms/500VDC

Efficiency

74% typ.

Safety Approvals

Design refer to LVD.

Physical Specifications

Size (mm)

159*97*38mm

Weight (g)

0.53Kg; 24pcs/12.7Kg/0.75CUFT

Notes

1. All parameters NOT specially mentioned are measured at 12, 24, 48VDC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Specifications

Output Voltage

5V

Output Amps

10A

Load Regulation

±0.5%

Line Regulation

±0.5%

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Voltage Tolerance

±2% (Note 3)

Over Voltage Protection

5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over Current Protection

105~150% rated output power. Protection type: Fold back current limiting, recovers automatically after fault condition is removed

DC Voltage Adjust (typ.)

4.5~5.5VDC

Start Up, Rise Time

2.5s, 50ms at full load

Environmental Specifications

Operating Temperature

-20 to +60°C (refer to output derating curve)

Storage Temperature

-20 to +85°C

Working Humidity

20~90% RH non-condensing

Storage Humidity

10~95% RH

EMC

Compliance to EN61000-4-2, 3, 4, 5, 6, 8; EN50204, EN55024, heavy industry level, criteria A

EMI

Compliance to EN55022 (CISPR22) Class B

MTBF

365.6K hrs min. MIL-HDBK-217F (25°C)

Vibration