350W Single Output DC-DC Converter
SD350DRL 350w Power Supplies
|
Model Number |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 2.0% (Note 3) |
4.5 ~ 5.5VDC |
0~57A |
74% typ. |
|
|
16.8~20V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
11~16VDC |
0~27.5A |
80% typ. |
|
|
31.5~37.5V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
23~30VDC |
0~14.6A |
80% typ. |
|
|
53~65V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
43~53VDC |
0~7.3A |
84% typ. |
|
|
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 2.0% (Note 3) |
4.5 ~ 5.5VDC |
0~60A |
76% typ. |
|
|
16.8~20V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
11~16VDC |
0~27.5A |
81% typ. |
|
|
31.5~37.5V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
23~30VDC |
0~14.6A |
81% typ. |
|
|
53~65V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
43~53VDC |
0~7.3A |
82% typ. |
|
|
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 2.0% (Note 3) |
4.5 ~ 5.5VDC |
0~60A |
78% typ. |
|
|
16.8~20V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
11~16VDC |
0~29A |
83% typ. |
|
|
31.5~37.5V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
23~30VDC |
0~14.6A |
87% typ. |
|
|
53~65V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 1.0% (Note 3) |
43~53VDC |
0~7.3A |
89% typ. |
|
2.1 wide input range |
|
|
Protections: Short circuit/Over load/Over voltage/Over Temperature |
|
|
1500VDC I/O isolation |
|
|
Forced air cooling by built in DC fan |
|
|
100% full load burn-in test |
|
|
24V and 48V input voltage design refer to LVD |
|
Model Number |
Input Voltage Range |
Inrush Current |
Input Current |
Output Voltage |
Output Amps |
Line Regulation |
Ripple and Noise |
|
SD350B-5/DRL |
19~36VDC |
14.4A/24V |
5V |
57A |
+/- 0.5% |
100mVp-p max. (Note 2) |
|
|
SD350B-12/DRL |
19~36VDC |
16A/24V |
12V |
27.5A |
+/-0.3% |
120mVp-p max. (Note 2) |
|
|
SD350B-24/DRL |
19~36VDC |
17.6A/24V |
24V |
14.6A |
+/-0.2% |
150mVp-p max. (Note 2) |
|
|
SD350B-48/DRL |
19~36VDC |
17.6A/24V |
48V |
7.3A |
+/-0.2% |
200mVp-p max. (Note 2) |
|
|
SD350C-5/DRL |
36~72VDC |
45A/48VDC |
7.6A/48V |
5V |
60A |
+/- 0.5% |
100mVp-p max. (Note 2) |
|
SD350C-12/DRL |
36~72VDC |
45A/48VDC |
8.8A/48V |
12V |
27.5A |
+/-0.3% |
120mVp-p max. (Note 2) |
|
SD350C-24/DRL |
36~72VDC |
45A/48VDC |
8.6A/48V |
24V |
14.6A |
+/-0.2% |
150mVp-p max. (Note 2) |
|
SD350C-48/DRL |
36~72VDC |
45A/48VDC |
8.6A/48V |
48V |
7.3A |
+/-0.2% |
200mVp-p max. (Note 2) |
|
SD350D-5/DRL |
72~144VDC |
45A/96VDC |
4A/96V |
5V |
60A |
+/- 0.5% |
100mVp-p max. (Note 2) |
|
SD350D-12/DRL |
72~144VDC |
45A/96VDC |
4.4A/96V |
12V |
29.2A |
+/-0.3% |
120mVp-p max. (Note 2) |
|
SD350D-24/DRL |
72~144VDC |
45A/96VDC |
4.2A/96V |
24V |
14.6A |
+/-0.2% |
150mVp-p max. (Note 2) |
|
SD350D-48/DRL |
72~144VDC |
45A/96VDC |
4.2A/96V |
48V |
7.3A |
+/-0.2% |
200mVp-p max. (Note 2) |
SD350/DRL series
|
Input Specifications General Specifications
Environmental Specifications
|
Notes Output Specifications
Physical Specifications
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |