25W Single Output DC-DC Converter
SD25DRL 25w Power Supplies
|
2.1 wide input range |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
1500VDC I/O isolation |
|
|
Built-in EMI filter, low ripple noise |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 83KHz, low cost, High reliability |
|
Model Number |
Picture Name |
Input Voltage Range |
Input Current |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
|
=B12&"p1.jpg" |
9.2~18VDC |
3.2A/12V |
5V |
5A |
+/- 0.5% |
+/- 0.5% |
100mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
19~36VDC |
3.2A/12V |
5V |
5A |
+/- 0.5% |
+/- 0.5% |
100mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
36~72VDC |
3.2A/12V |
5V |
5A |
+/- 0.5% |
+/- 0.5% |
100mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
9.2~18VDC |
1.6A/24V |
12V |
2.1A |
+/-0.3% |
+/-0.3% |
120mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
19~36VDC |
1.6A/24V |
12V |
2.1A |
+/-0.3% |
+/-0.3% |
120mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
36~72VDC |
1.6A/24V |
12V |
2.1A |
+/-0.3% |
+/-0.3% |
120mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
9.2~18VDC |
0.8A/24V |
24V |
1.1A |
+/-0.2% |
+/-0.2% |
120mVp-p max. (Note 2) |
|
|
=B12&"p1.jpg" |
19~36VDC |
0.8A/24V |
24V |
1.1A |
+/-0.2% |
+/-0.2% |
150mVp-p max. (Note 2) |
|
|
SD-200D |
36~72VDC |
0.8A/24V |
24V |
1.1A |
+/-0.2% |
+/-0.2% |
150mVp-p max. (Note 2) |
|
Model Number |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
MTBF |
Efficiency |
|
SD25A-5/DRL |
5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 2.0% (Note 3) |
4.5 ~ 5.5VDC |
0~5A |
374.3K hrs min. MIL-HDBK-217F (25°C) |
71% typ. |
|
SD25B-5/DRL |
5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 2.0% (Note 3) |
4.5 ~ 5.5VDC |
0~5A |
365.9K hrs min. MIL-HDBK-217F (25°C) |
72% typ. |
|
SD25C-5/DRL |
5.75~6.75V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 2.0% (Note 3) |
4.5 ~ 5.5VDC |
0~5A |
377.5K hrs min. MIL-HDBK-217F (25°C) |
74% typ. |
|
SD25A-12/DRL |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
11~16VDC |
0~2.1A |
374.3K hrs min. MIL-HDBK-217F (25°C) |
72% typ. |
|
SD25B-12/DRL |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
11~16VDC |
0~2.1A |
365.9K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
|
SD25C-12/DRL |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
11~16VDC |
0~2.1A |
377.5K hrs min. MIL-HDBK-217F (25°C) |
78% typ. |
|
SD25A-24/DRL |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
23~30VDC |
0~1.1A |
374.3K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
|
SD25B-24/DRL |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
23~30VDC |
0~1.1A |
365.9K hrs min. MIL-HDBK-217F (25°C) |
78% typ. |
|
SD25C-24/DRL |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
23~30VDC |
0~1.1A |
377.5K hrs min. MIL-HDBK-217F (25°C) |
81% typ. |
SD25/DRL series
|
Input Specifications General Specifications
Environmental Specifications
|
Output Specifications Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
|