Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

SD200DRL 200w Power Supplies

200W Single Output DC-DC Converter

2:1 wide input range

Protections: Short Circuit/Over load/Over voltage/Over temperature

1500VDC I/O isolation

Cooling by free air convection

100% full load burn-in test

24V and 48V input voltage design refer to LVD

Model Number

Input Voltage Range

Inrush Current

Input Current

Output Amps

Over Temperature Protection

Efficiency

SD200B-24/DRL

19~36VDC

10.8A/24V, 10.6A/24V, 10.4A/24V, 10.4A/24V

34A, 16.7A, 8.4A, 4.2A

95°C ±5°C TSW1,100°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down.

79% typ., 82% typ., 85% typ., 86% typ.

SD200C-48/DRL

36~72VDC

45A/48VDC typ.

5.4A/48V, 5.2A/48V, 5A/48V, 5A/48V

40A, 16.4A, 8.4A, 4.2A

95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down.

81% typ., 84% typ., 86% typ., 86% typ.

SD200D-48/DRL

72~144VDC

45A/96VDC typ.

2.6A/96V, 2.5A/96V, 2.4A/96V, 2.4A/96V

40A, 16.7A, 8.4A, 4.2A

95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down.

82% typ., 82% typ., 84% typ., 90% typ.

SD200/DRL series

Input Specifications

Input Voltage Range

19~36VDC

Input Current

10.8A/24V

General Specifications

Isolation

1.5KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

79% typ.

Safety Approvals

24V and 48V input design refer to LVD (Note 4)

Environmental Specifications

Operating Temperature

-20 ~ +60°C (Refer to output load derating curve)

Storage Temperature

-40~+85°C

Working Humidity

20 ~ 90% RH non-condensing

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN55022 (CISPR22) Class B (Note 4)

MTBF

218.2K hrs min. MIL-HDBK-217F (25°C)

Vibration

10 ~ 500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2, 3, 4, 6, 8; ENV50204 heavy industry level, criteria A (Note 4)

Output Specifications

Physical Specifications

Size (mm)

215x115x50

Weight (g)

1.1Kg; 12pcs/14.4Kg/0.92CUFT

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

5V

Output Amps

34A

Load Regulation

±1%

Line Regulation

±0.5%

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

5.75~6.75V Protection type: Shut down o/p voltagem re-power on to recover

Over Current Protection

105 ~ 135% rated output power. Protection type: Shut down o/p voltage, re-power on to recover

Over Temperature Protection

95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down.

Voltage Tolerance

±2.0% (Note 3)

DC Voltage Adjust

4.5 ~ 5.5VDC

Minimum Load Requirement

0~34A

Rise Time

300ms, 50ms at full load