200W Single Output DC-DC Converter
SD200DRL 200w Power Supplies
|
2:1 wide input range |
|
|
Protections: Short Circuit/Over load/Over voltage/Over temperature |
|
|
1500VDC I/O isolation |
|
|
Cooling by free air convection |
|
|
100% full load burn-in test |
|
|
24V and 48V input voltage design refer to LVD |
|
Model Number |
Input Voltage Range |
Inrush Current |
Input Current |
Output Amps |
Over Temperature Protection |
Efficiency |
|
19~36VDC |
10.8A/24V, 10.6A/24V, 10.4A/24V, 10.4A/24V |
34A, 16.7A, 8.4A, 4.2A |
95°C ±5°C TSW1,100°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down. |
79% typ., 82% typ., 85% typ., 86% typ. |
||
|
36~72VDC |
45A/48VDC typ. |
5.4A/48V, 5.2A/48V, 5A/48V, 5A/48V |
40A, 16.4A, 8.4A, 4.2A |
95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down. |
81% typ., 84% typ., 86% typ., 86% typ. |
|
|
72~144VDC |
45A/96VDC typ. |
2.6A/96V, 2.5A/96V, 2.4A/96V, 2.4A/96V |
40A, 16.7A, 8.4A, 4.2A |
95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1, 95°C ±5°C TSW1 Detect on main power transistor. Protection type: Shut down o/p voltage, recovers automatically after temperature goes down. |
82% typ., 82% typ., 84% typ., 90% typ. |
SD200/DRL series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
|