150W Single Output DC-DC Converter
SD150DRL 150w Power Supplies
|
2.1 wide input range |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
1500VDC I/O isolation |
|
|
Built-in EMI filter, low ripple noise |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 83KHz, 24V and 48V input voltage design refer to LVD, low cost, High reliability |
|
Model Number |
Input Voltage Range |
Inrush Current |
Input Current |
Leakage Current |
Output Voltage |
Output Amps |
Load Regulation |
|
19~ 36VDC |
6.8A/ 24VDC |
12V |
12.5A |
+/- 0.5% |
|||
|
36~ 72VDC |
3.4A/ 48VDC |
12V |
12.5A |
+/- 0.5% |
|||
|
72~ 144VDC or 85~ 132VAC |
22.5A/ 96VDC typ. |
1.7A/ 96VDC |
<0.75mA/ 240VAC |
12V |
12.5A |
+/- 0.5% |
|
|
19~ 36VDC |
6.8A/ 24VDC |
24V |
6.3A |
+/-0.3% |
|||
|
36~ 72VDC |
3.4A/ 48VDC |
24V |
6.3A |
+/-0.3% |
|||
|
72~ 144VDC or 85~ 132VAC |
22.5A/ 96VDC typ. |
1.7A/ 96VDC |
<0.75mA/ 240VAC |
24V |
6.3A |
+/-0.3% |
|
Model Number |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust |
Minimum Load Requirement |
|
SD150B-12/DRL |
+/- 0.5% |
120mVp-p max. (Note 2) |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
11~ 16VDC |
0~ 12.5A |
|
SD150C-12/DRL |
+/- 0.5% |
120mVp-p max. (Note 2) |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
11~ 16VDC |
0~ 12.5A |
|
SD150D-12/DRL |
+/- 0.5% |
120mVp-p max. (Note 2) |
16.8~20V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
11~ 16VDC |
0~ 12.5A |
|
SD150B-24/DRL |
+/-0.3% |
150mVp-p max. (Note 2) |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
23~ 30VDC |
0~ 6.3A |
|
SD150C-12/DRL |
+/-0.3% |
150mVp-p max. (Note 2) |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
23~30VDC |
0~6.3A |
|
SD150D-24/DRL |
+/-0.3% |
150mVp-p max. (Note 2) |
31.5~37.5V/10% load, Protection type: Hiccup mode, recovers automatically after fault condition is removed |
23~30VDC |
0~6.3A |
SD150/DRL series
|
General Specifications
Input Specifications
Environmental Specifications
|
Output Specifications Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
|