100W Single Output DC-DC Converter
SD100 100w Power Supplies
|
Model Number |
Input Voltage Range |
DC Current |
Inrush Current |
Leakage Current |
Minimum Load Requirement |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
|
19~36VDC |
4.8A/24V typ. |
0~20A |
5V |
20A |
±0.5% |
±0.5% |
|||
|
36~72VDC |
4.8A/24V typ. |
0~20A |
5V |
20A |
±0.5% |
±0.5% |
|||
|
72~144VDC or 85~132VAC |
4.8A/24V typ. |
18A/96 VDC typ. |
<0.75mA/120 VAC (SD-100D) |
0~20A |
5V |
20A |
±0.5% |
±0.5% |
|
|
19~36VDC |
2.4A/48V typ. |
0~8.5A |
12V |
8.5A |
±0.3% |
±0.3% |
|||
|
36~72VDC |
2.4A/48V typ. |
0~8.5A |
12V |
8.5A |
±0.3% |
±0.3% |
|||
|
72~144VDC or 85~132VAC |
2.4A/48V typ. |
18A/96 VDC typ. |
<0.75mA/120 VAC (SD-100D) |
0~8.5A |
12V |
8.5A |
±0.3% |
±0.3% |
|
|
19~36VDC |
1.2A/96V typ. |
0~4.2A |
24V |
4.2A |
±0.2% |
±0.2% |
|||
|
36~72VDC |
1.2A/96V typ. |
0~4.2A |
24V |
4.2A |
±0.2% |
±0.2% |
|||
|
72~144VDC or 85~132VAC |
1.2A/96V typ. |
18A/96 VDC typ. |
<0.75mA/120 VAC (SD-100D) |
0~4.2A |
24V |
4.2A |
±0.2% |
±0.2% |
|
2:1 wide input range |
|
|
Protections: Short circuit/Over load/Over voltage |
|
|
1500VDC I/O isolation |
|
|
Built-in EMI filter, low ripple noise |
|
|
100% full load burn-in test |
|
|
Fixed switching frequency at 83KHz |
SD100 series
|
Model Number |
Ripple and Noise |
Voltage Tolerance |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Hold Time |
Start Up, Rise Time |
MTBF |
Efficiency |
|
SD-100B-5 |
100mVp-p max. (Note 2) |
±2% (Note 3) |
5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
4.5~5.5 VDC |
356.7K hrs min. MIL-HDBK-217F (25°C) |
74% typ. |
||
|
SD-100C-5 |
100mVp-p max. (Note 2) |
±2% (Note 3) |
5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
4.5~5.5 VDC |
355.5K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
||
|
SD-100D-5 |
100mVp-p max. (Note 2) |
±2% (Note 3) |
5.75~6.75V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
4.5~5.5 VDC |
24ms at full load, typ. |
2s, 50ms at full load |
341.9K hrs min. MIL-HDBK-217F (25°C) |
76% typ. |
|
SD-100B-12 |
120mVp-p max. (Note 2) |
±1% (Note 3) |
16.8~20V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
11~16 VDC |
356.7K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
||
|
SD-100C-12 |
120mVp-p max. (Note 2) |
±1% (Note 3) |
16.8~20V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
11~16 VDC |
355.5K hrs min. MIL-HDBK-217F (25°C) |
77% typ. |
||
|
SD-100D-12 |
120mVp-p max. (Note 2) |
±1% (Note 3) |
16.8~20V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
11~16 VDC |
24ms at full load, typ. |
2s, 50ms at full load |
341.9K hrs min. MIL-HDBK-217F (25°C) |
80% typ. |
|
SD-100B-24 |
150mVp-p max. (Note 2) |
±1% (Note 3) |
31.5~37.5V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
23~30 VDC |
356.7K hrs min. MIL-HDBK-217F (25°C) |
78% typ. |
||
|
SD-100C-24 |
150mVp-p max. (Note 2) |
±1% (Note 3) |
31.5~37.5V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
23~30 VDC |
355.5K hrs min. MIL-HDBK-217F (25°C) |
83% typ. |
||
|
SD-100D-24 |
150mVp-p max. (Note 2) |
±1% (Note 3) |
31.5~37.5V/10% load. Protection type: Hiccup mode, recovers automatically after fault condition is removed |
23~30 VDC |
24ms at full load, typ. |
2s, 50ms at full load |
341.9K hrs min. MIL-HDBK-217F (25°C) |
75% typ. |
|
Input Specifications
General Specifications
Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 24, 48, 96VDC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |
Output Specifications
Environmental Specifications
|