240W Single Output Switching Power Supply
S240DRL 240w Switch Mode Power Supplies
|
Auto switched 88 ~ 264VAC input |
|
|
Built-in passive PFC choke |
|
|
Protections; Short circuit / Over load/ Over voltage/ Over temperature |
|
|
Forced air cooling by built in DC fan |
|
|
Built-in cooling Fan ON-OFF control |
|
|
LED indicator for power on, Fized switching frequency at 75KHz |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
S240-5 |
5V |
40A |
+/- 1.0% |
+/- 0.5% |
150mVp-p max. (Note 2) |
6~7V Hiccup mode, recovers automatically after fault condition is removed |
+/- 2.0% (Note 3) |
4.5~5.8V |
0~40A |
78% typ. |
|
S240-7.5 |
7.5V |
30A |
+/- 1.0% |
+/- 0.5% |
200mVp-p max. (Note 2) |
9.4~10.9V Hiccup mode, recovers automatically after fault condition is removed |
+/- 2.0% (Note 3) |
6~9V |
0~30A |
80% typ. |
|
S240-12 |
12V |
18A |
+/- 0.5% |
+/- 0.5% |
150mVp-p max. (Note 2) |
14.4~16.6V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
10~14V |
0~18A |
82% typ. |
|
S240-15 |
15V |
15A |
+/- 0.5% |
+/- 0.5% |
150mVp-p max. (Note 2) |
18.5~21.5V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
12~18V |
0~15A |
83% typ. |
|
S240-24 |
24V |
10A |
+/- 0.5% |
+/- 0.5% |
180mVp-p max. (Note 2) |
31.2~36V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
20~28V |
0~10A |
84% typ. |
|
S240-30 |
30V |
8A |
+/- 0.5% |
+/- 0.5% |
180mVp-p max. (Note 2) |
34.5~40.5V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
27~33V |
0~8A |
85% typ. |
|
S240-48 |
48V |
5A |
+/- 1.0% |
+/- 1.0% |
240mVp-p max. (Note 2) |
57.6~67.2V Hiccup mode, recovers automatically after fault condition is removed |
+/- 1.0% (Note 3) |
41~56V |
0~5A |
87% typ. |
S240/DRL series
|
General Specifications
Input Specifications Environmental Specifications
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. Physical Specifications Output Specifications