Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

RSP1500 1500 Watt Enclosed Power Supplies

1500W Single Output Power Supply

Universal AC input

Protections:Short circuit/Over load/Over voltage/Over temperature

Built-in active PFC function, PF>0.95

Forced air cooling by built-in DC ball bearing fan

Built-in remote sense function

Built-in remote ON OFF control

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

DC Voltage Adjust (typ.)

Hold Up Time

Efficiency

RSP1500-5 12vdc 240 Amps

±2.0%

150mVpk-pk (Note 1)

5.75 ~ 6.75Volt(DC) Constant current limit, Shutdown o/p volage, re-power

4.5~5.5Volt(DC)

10mS

0.8

RSP1500-12 13.5vdc 125 Amps

±0.5%

150mVpk-pk (Note 1)

13.8 ~ 16.8Volt(DC) Constant current limit, Shutdown o/p volage, re-power

10~13.5Volt(DC)

10mS

0.87

RSP1500-15 15vdc 100 Amps

±0.5%

150mVpk-pk (Note 1)

17 ~ 20.5Volt(DC) Constant current limit, Shutdown o/p volage, re-power

13.5~16.5Volt(DC)

14mS

0.87

RSP1500-24 24vdc 63 Amps

±0.5%

150mVpk-pk (Note 1)

27.6 ~ 32.4Volt(DC) Constant current limit, Shutdown o/p volage, re-power

20~26.4Volt(DC)

14mS

0.9

RSP1500-27 27vdc 56 Amps

±0.5%

150mVpk-pk (Note 1)

31 ~ 36.5Volt(DC) Constant current limit, Shutdown o/p volage, re-power

24~30Volt(DC)

16mS

0.9

RSP1500-48 48vdc 32 Amps

±0.5%

200mVpk-pk (Note 1)

57.6~ 67.2Volt(DC) Constant current limit, Shutdown o/p volage, re-power

43~56Volt(DC)

16mS

0.91

RSP1500 series

Input Specifications

Input Voltage Range

90 ~ 264VAC 127~370vdc

Input Reflected Ripple Current

17 Amps @ 115VAC, 8.0 Amps @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

30Amps/115VAC; 60Amps 230VAC (cold start)

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

80%

Switching Frequency

UL60950-1, TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-20°C to +70°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

MTBF

62.6KHrs min,MIL-HDBK-217F(25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, EN55024 light Industry Level, Criteria A

Output Specifications

Output Voltage

12vdc

Output Amps

240 Amps

Load Regulation

±2.0%

Line Regulation

±0.5%

Temperature Coefficient

±0.05% / °C (0-50°C)

Ripple and Noise

150mVpk-pk (Note 1)

Over Voltage Protection

5.75 ~ 6.75Volt(DC) Constant current limit, Shutdown o/p volage, re-power

Over Current Protection

105~135% rated output power Constent current limiting,auto recover

DC Voltage Adjust (typ.)

4.5~5.5Volt(DC)

Hold Up Time

10mS

Remore Shutdown

Please see the Function Manual

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Physical Specifications

Size (mm)

278 x 127 x 83.5mm

Size (Inches)

10.95”x5 ”x3.29”

Weight (g)

2600g

Weight (oz)

91.71oz

Notes