Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

RS25 25 Watt Switch Mode Power Supplies

25W Single Output Switching Power Supply

Universal AC input

Protections:Short circuit/Over load/Over voltage

Cooling by free air convection

LED indicator for power on

All using 105°C long life electrolytic capacitors

High efficiency, long life and high reliability

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

DC Voltage Adjust (typ.)

Efficiency

RS25-3.3

3.3vdc

6 Amps

±2.0% (Note 4)

80mV pk-pk (Note 1)

3.8 ~ 4.45Volt(DC) Shut off o/p voltage, clamping zener diode

2.85~3.6Volt(DC)

0.72

RS25-5

5vdc

5 Amps

±1.0% (Note 4)

80mV pk-pk (Note 1)

5.75 ~ 6.75Volt(DC) Shut off o/p voltage, clamping zener diode

4.75~5.5Volt(DC)

0.77

RS25-12

12vdc

2.1 Amps

±0.5% (Note 4)

120mV pk-pk (Note 1)

13.8 ~ 16.2Volt(DC) Shut off o/p voltage, clamping zener diode

10.8~13.2Volt(DC)

0.79

RS25-15

15vdc

1.7 Amps

±0.5% (Note 4)

120mV pk-pk (Note 1)

17.25 ~ 20.25Volt(DC) Shut off o/p voltage, clamping zener diode

13.5~16.5Volt(DC)

0.82

RS25-24

24vdc

1.1 Amps

±0.5% (Note 4)

120mV pk-pk (Note 1)

27.6~ 32.4Volt(DC) Shut off o/p voltage, clamping zener diode

22~27.6Volt(DC)

0.84

RS25-48

48vdc

0.57 Amps

±0.5% (Note 4)

200mV pk-pk (Note 1)

55.2~ 64.8Volt(DC) Shut off o/p voltage, clamping zener diode

42~54Volt(DC)

0.85

RS25 series

Input Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

72%

Switching Frequency

UL60950-1, TUV EN60950-1 Approved

Operating Temperature

-20°C to +70°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH non cond

MTBF

309.7KHrs min,MIL-HDBK-217F(25°C)

EMS

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204 light Industry Level, Criteria A

Input Voltage Range

90~ 264 VAC; 125~373vdc

Input Reflected Ripple Current

0.7 Amps. @ 115VAC, 0.4 Amps. @ 230VAC

Frequency Range

47-63 Hz

Inrush Current

30Amps/230VAC (cold start)

General Specifications

Environmental Specifications

Output Specifications

Output Voltage

3.3vdc

Output Amps

6 Amps

Load Regulation

±2.0% (Note 4)

Line Regulation

±0.5% (Note 3)

Temperature Coefficient

±0.03% / °C (0-50°C)

Ripple and Noise

80mV pk-pk (Note 1)

Over Voltage Protection

3.8 ~ 4.45Volt(DC) Shut off o/p voltage, clamping zener diode

Over Current Protection

110 ~ 180% rated output power Hiccup mode, auto recover

DC Voltage Adjust (typ.)

2.85~3.6Volt(DC)

Hold Up Time

80mS/230VAC, 14mS/115VAC

Physical Specifications

Size (mm)

78 x 51 x 28mm

Size (Inches)

3.07” x 2.01 ” x 1.10 ”

Weight (g)

200g

Weight (oz)

7.05oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.