RQ125 125 Watt Switch Mode Enclosed Power Supplies
|
LED indicator for power on |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
All using 105°C long life electrolytic capacitors |
|
|
Cooling by free air convection |
|
|
High efficiency, long life and high reliability |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Ripple and Noise |
Efficiency |
| RQ125-B | 5vdc/12vdc/-5vdc/-12vdc | 11 Amps/4.5 Amps/1.0 Amps/0.5 Amps |
±1.0%±3.0%/±6.0%/±2.0% (Note 4) |
80mVpk-pk/120mVpk-pk/80mVpk-pk/80mVpk-pk (Note 1) |
0.79 |
| RQ125-C | 5vdc/15vdc/-5vdc/-15vdc | 10 Amps/4.0 Amps/1.0 Amps/0.5 Amps |
±1.0%±3.0%/±6.0%/±2.0% (Note 4) |
80mVpk-pk/120mVpk-pk/80mVpk-pk/80mVpk-pk (Note 1) |
0.8 |
| RQ125-D | 5vdc/12vdc/24vdc/-12vdc | 8 Amps/2.5 Amps/2.0 Amps/0.5 Amps |
±1.0%±3.0%/±5.0%/±2.0% (Note 4) |
80mVpk-pk/120mVpk-pk/150mVpk-pk/80mVpk-pk (Note 1) |
0.82 |
RQ125 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |