RID125 125 Watt Switch Mode Enclosed Power Supplies
|
Isolated Output |
|
|
Universal AC input |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
Cooling by free air convection |
|
|
LED indicator for power on |
|
|
All using 105°C long life electrolytic capacitors |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Hold Up Time |
Operating Temperature |
Efficiency |
|
12vdc/ 5vdc |
9.2 Amps/ 3 Amps |
±1.0%/ ±2.0% (Note 4) |
±2.0%/ ±3.0% (Note 3) |
1200mV pk-pk/80mV pk-pk (Note 1) |
CH1: 13.8~16.2V |
5Volts: 11.4~ 13.2Volts (DC) |
35mS/ 230VAC 30mS/ 115VAC @ FL |
-25°C to +70°C |
0.8 |
|
|
24vdc/ 5vdc |
4.6 Amps/ 3 Amps |
±1.0%/ ±2.0% (Note 4) |
±2.0%/ ±3.0% (Note 3) |
120mV pk-pk/80mV pk-pk (Note 1) |
CH1: 27.6~32.4V |
5Volts: 22.8~ 26.4Volts (DC) |
35mS/ 230VAC 30mS/ 115VAC @ FL |
-25°C to +70°C |
0.83 |
|
|
12vdc/ 24vdc |
3.7 Amps/ 3.7 Amps |
±1.0%/ ±5.0% (Note 4) |
±2.0%/ +8, -5% (Note 3) |
120mV pk-pk/200mV pk-pk (Note 1) |
CH1: 13.8~16.2V |
5Volts: 11.4~ 13.2Volts (DC) |
36mS/ 230VAC 30mS/ 115VAC@FL |
-20°C to +70°C |
0.85 |
|
|
12vdc/ 48vdc |
2.3 Amps/ 2.3 Amps |
±1.0%/ ±5.0% (Note 4) |
±2.0%/ +8, -5% (Note 3) |
120mV pk-pk/240mV pk-pk (Note 1) |
CH1: 13.8~16.2V |
5Volts: 11.4~ 13.2Volts (DC) |
36mS/ 230VAC 30mS/ 115VAC@FL |
-20°C to +70°C |
0.85 |
|
|
24vdc/ 48vdc |
2.0 Amps/ 2.0 Amps |
±1.0%/ ±3.0% (Note 4) |
±1.0%/ ±4.0% (Note 3) |
200mV pk-pk/240mV pk-pk (Note 1) |
CH1: 27.6~32.4V |
5Volts: 22.8~ 26.4Volts (DC) |
36mS/ 230VAC 30mS/ 115VAC@FL |
-20°C to +70°C |
0.86 |
RID125 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
Notes |