Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

REL150 150w Power Supplies

150 Watts Output Power

Universal 85-265VAC Input

Single, Dual, Triple, and Quad Outputs

Active Power Factor Correction

2.5VDC to 48VDC Outputs

Model Number

Output Voltage

Output Amps

Remote Sense

REL150-1001

2.5V (Output # 1)

30 Amps (Output # 1)

250mV compensation

REL150-1002

3.3V(Output # 1)

30 Amps (Output # 1)

250mV compensation

REL150-1003

5V (Output # 1)

30 Amps (Output # 1)

250mV compensation

REL150-1004

12V (Output # 1)

12.5 Amps (Output # 1)

250mV compensation

REL150-1005

15V (Output # 1)

10 Amps (Output # 1)

250mV compensation

REL150-1006

24V (Output # 1)

6.3 Amps (Output # 1)

250mV compensation

REL150-1007

28V (Output # 1)

5.4 Amps (Output # 1)

250mV compensation

REL150-1008

48V (Output # 1)

3.1 Amps (Output # 1)

250mV compensation

REL150-2001

3.3V (Output # 1)/5V (Output # 2)

15 Amps (Output # 1)/8 Amps (Output # 2)

REL150-2002

5V (Output # 1)/12V (Output #2)

15 Amps (Output # 1)/5 Amps (Output #2)

REL150-2003

5V (Output # 1)/24V (Output #2)

15 Amps (Output # 1)/3 Amps (Output #2)

REL150-2004

12V (Output # 1)/-12V (Output #2)

7.5 Amps (Output # 1)/5 Amps (Output #2)

REL150-2005

15V (Output # 1)/-15V (Output #2)

5 Amps (Output # 1)/5 Amps (Output #2)

REL150-3001

5V (Output # 1)/12V (Output #2)/-12V (Output #4)

15 Amps (Output # 1)/4 Amps (Output #2)/3 Amps (Output #4)

REL150-3002

5V (Output # 1)/15V (Output #2)/-15V (Output #4)

15 Amps (Output # 1)/3 Amps (Output #2)/2 Amps (Output #4)

REL150-4001

3.3V (Output # 1)/5V (Output #2)/12V (Output #3)/-12V (Output #4)

15 Amps (Output # 1)/8 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150-4002

5V (Output # 1)/3.3V (Output #2)/12V (Output #3)/-12V (Output #4)

15 Amps (Output # 1)/8 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150-4003

5V (Output # 1)/3.3V (Output #2)/15V (Output #3)/-15V (Output #4)

15 Amps (Output # 1)/8 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150-4004

5V (Output # 1)/-5V (Output #2)/12V (Output #3)/-12V (Output #4)

15 Amps (Output # 1)/8 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150-4005

5V (Output # 1)/-5V (Output #2)/15V (Output #3)/-15V (Output #4)

15 Amps (Output # 1)/8 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150-4006

5V (Output # 1)/24V (Output #2)/12V (Output #3)/-12V (Output #4)

15 Amps (Output # 1)/3 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150-4007

5V (Output # 1)/24V (Output #2)/15V (Output #3)/-15V (Output #4)

15 Amps (Output # 1)/3 Amps (Output #2)/2 Amps (Output #3)/2 Amps (Output #4)

REL150 series

Input Specifications

Input Voltage Range

85-264 VAC

Frequency Range

47-63Hz.

Inrush Current

30A @ 115VAC, typ, 40A @ 230VAC, typ (note 4)

Leakage Current

<300uA @ 240VAC

Power Factor Correction

>0.95@115VAC

Environmental Specifications

Operating Temperature

0 to +60 °C (note 4)

EMC

EN55022/B, EN61000-3-2,3/A, EN61000--4-2,3,4,5,6,8,1 1/Cr A

Storage Temperature

-40 to +85 °C (note 4)

Relative Humidity

10-95%, Description (note 4)

MTBF

100KHrs, MIL-Std 217F

Vibration

To MIL-Std 810E

General Specifications

Isolation

3000VAC (note 5)

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Efficiency

82%, typ (or See Chart/Curve)

Safety Approvals

UL60950/EN60950 Approved

Output Specifications

Output Voltage

2.5V (Output # 1)

Output Amps

30 Amps (Output # 1)

Minimum Load Requirement

10%

Load Regulation

± 1%, typ

Line Regulation

± 0.5%, typ

Cross Regulation

±5%

Preset Accuracy

±1%, typ

Temperature Coefficient

± 0.02%/°C

Ripple and Noise

100mV Pk-Pk, typ

Over Voltage Protection

110-150%, Type 2 & 3

Over Current Protection

110-160% typ, Auto Recovery

Start Up

5Sec, typ

Short Circuit Protection

Continuous (note 4)

Peak Load

See Model Selection Chart 7

Hold Up Time

16mS

DC Voltage Adjust (typ.)

± 5%, typ

Remote Sense

250mV compensation

Physical Specifications

Size (mm)

152.39 x 97.28 x 33.52 mm

Size (Inches)

6”x3.83”x1.32”

Construction

Open Frame

Weight (g)

521.63g

Weight (oz)

18.4oz

Notes

1. All specifications typical @ 25°C, Nominal Line & Load, unless otherwise noted.

2. O/P noise measured directly at pins/terminals with 0.1uFbypass, pk-pk @ 20MHz bandwidth.

3. Ripple and Noise dependant upon output voltage as specified per particular model.

4. These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed or implied.

5. Isolation for up to 1 minute duration.

6. No termination necessary with control pin to maintain constant “ON” operation (if applicable to this model)

7. Max load (peak) specified for 10mS max, 20% duty cycle, minimum load on all outputs.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.