200W Quad Output with PFC Function
QP200DRL 200w Power Supplies
|
Model Number |
Picture Name |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
QP200-D CH1 |
=B12&"p1.jpg" |
5V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
3~20A (Note 4) |
75% typ. |
|
QP200-D CH2 |
=B12&"p1.jpg" |
12V |
15A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
1.14~ 13.2V |
0~20A (Note 4) |
75% typ. |
|
QP200-D CH3 |
=B12&"p1.jpg" |
24V |
6A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+10,-6% (Note 3) |
0.4~5A (Note 4) |
75% typ. |
||
|
QP200-D CH4 |
=B12&"p1.jpg" |
-12V |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0~1A (Note 4) |
75% typ. |
||
|
QP200-F CH1 |
=B12&"p1.jpg" |
5V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
3~20A (Note 4) |
75% typ. |
|
QP200-F CH2 |
=B12&"p1.jpg" |
15V |
15A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
14.25~ 16.5V |
0~20A (Note 4) |
75% typ. |
|
Universal AC input/Full range |
|
|
Built-in active PFC function, PF>0.95 |
|
|
Protections; Short circuit / Over load/ Over voltage/ Over temperature |
|
|
Forced air cooling by built in DC fan |
|
|
CH1,2 can be adjustable from -5~+10% |
|
|
With power good and fail signal output (Optional). Built-in remote sense function for CH1, 2. 100% full load burn-in test. CH4 can set to positive after consult us before delivery. Fixed switching frequency at PFC:67KHz PWM:134KHz(optional) |
QP200/DRL series
|
Model Number |
Picture Name |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
QP-200F CH3 |
=B12&"p1.jpg" |
24V |
5A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+10,-6% (Note 3) |
0.4~5A (Note 4) |
75% typ. |
||
|
QP-200F CH4 |
=B12&"p1.jpg" |
-15V |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0~1A (Note 4) |
75% typ. |
||
|
QP-200-3A CH1 |
=B12&"p1.jpg" |
5V |
10A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
3~20A (Note 4) |
72% typ. |
|
QP-200-3A CH2 |
=B12&"p1.jpg" |
3.3V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~20A (Note 4) |
72% typ. |
|
QP-200-3A CH3 |
=B12&"p1.jpg" |
12V |
4A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+8,-10% (Note 3) |
0.5~8A (Note 4) |
72% typ. |
||
|
QP-200-3A CH4 |
=B12&"p1.jpg" |
-5V |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0~1A (Note 4) |
72% typ. |
||
|
QP-200-3B CH1 |
5V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
3~20A (Note 4) |
72% typ. |
|
|
QP-200-3B CH2 |
3.3V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~20A (Note 4) |
72% typ. |
|
|
QP-200-3B CH3 |
12V |
6A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+8,-10% (Note 3) |
0.5~8A (Note 4) |
72% typ. |
|||
|
QP-200-3B CH4 |
-12V |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0~1A (Note 4) |
72% typ. |
|||
|
QP-200-3C CH1 |
5V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
3~20A (Note 4) |
72% typ. |
|
|
QP-200-3E CH3 |
=B12&"p1.jpg" |
24V |
4A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+10,-6% (Note 3) |
0.4~5A (Note 4) |
74% typ. |
||
|
QP-200-3E CH4 |
=B12&"p1.jpg" |
-15v |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0~1A (Note 4) |
74% typ. |
|
Model Number |
Picture Name |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
QP-200-3C CH2 |
3.3V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~20A (Note 4) |
72% typ. |
|
|
QP-200-3C CH3 |
15V |
5A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+10,-6% (Note 3) |
0.5~6A (Note 4) |
72% typ. |
|||
|
QP-200-3C CH4 |
-15V |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0~1A (Note 4) |
72% typ. |
|||
|
QP-200-3D CH1 |
5V |
10A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
0~1A (Note 4) |
74% typ. |
|
|
QP-200-3D CH2 |
3.3V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
3~20A (Note 4) |
74% typ. |
|
|
QP-200-3D CH3 |
24V |
4A |
+/-6.0% |
±2.0% |
150mVp-p max. (Note 2) |
+10,-6% (Note 3) |
0~20A (Note 4) |
74% typ. |
|||
|
QP-200-3D CH4 |
-12V |
0.7A |
+/-2.0% |
±1% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0.4~5A (Note 4) |
74% typ. |
|||
|
QP-200-3E CH1 |
=B12&"p1.jpg" |
5V |
10A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
0~1A (Note 4) |
74% typ. |
|
QP-200-3E CH2 |
=B12&"p1.jpg" |
3.3V |
15A |
+/-2.0% |
±1% |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~20A (Note 4) |
74% typ. |
|
Input Specifications
General Specifications
Environmental Specifications
|
Physical Specifications
Notes Output Specifications 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. the final equipment must be re-confirmed that it still meets EMC directives. 6. Derating may be needed under low input voltages. Plese check the derating curve for more details. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||