Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

QP200 200w Power Supplies

200W Quad Output with PFC Function

Universal AC input

Built-in PFC function, PF >0.95

Protections: Short circuit / Overload / Over voltage

Fixed switching frequency at PFC:67KHz PWM:134KHz

Forced air cooling by built-in DC fan

With power good and fail output(Optional)

Model Number

Output Voltage

Output Amps

Ripple and Noise

QP200-D

5 Volts(DC)/12 Volts(DC)/24 Volts(DC)/-12 Volts(DC)

15 Amps/4.0 Amps/3.0 Amps/0.7 Amps

100mVpk-pk/150mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200-F

5 Volts(DC)/15 Volts(DC)/24 Volts(DC)/-15 Volts(DC)

15 Amps/3.0 Amps/3.0 Amps/0.7 Amps

100mVpk-pk/150mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200-3A

5 Volts(DC)/3.3 Volts(DC)/12 Volts(DC)/-5 Volts(DC)

15 Amps/15 Amps/6.0 Amps/0.7 Amps

100mVpk-pk/100mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200-3B

5 Volts(DC)/3.3 Volts(DC)/12 Volts(DC)/-12 Volts(DC)

15 Amps/15 Amps/6.0 Amps/0.7 Amps

100mVpk-pk/100mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200-3C

5 Volts(DC)/3.3 Volts(DC)/15 Volts(DC)/-15 Volts(DC)

15 Amps/15 Amps/5.0 Amps/0.7 Amps

100mVpk-pk/100mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200-3D

5 Volts(DC)/3.3 Volts(DC)/24 Volts(DC)/-12 Volts(DC)

10 Amps/15 Amps/4.0 Amps/0.7 Amps

100mVpk-pk/100mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200-3E

5 Volts(DC)/3.3 Volts(DC)/-24 Volts(DC)/-15 Volts(DC)

10 Amps/15 Amps/4.0 Amps/0.7 Amps

100mVpk-pk/100mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

QP200 series

Input Specifications

Input Voltage Range

90-264VAC / 127-370 Volts(DC) (Note 4)

Input Reflected Ripple Current

3.5Amps max @115VAC, 2.0Amps max @230VAC

Frequency Range

47-63Hz

Inrush Current

30 Amps (cold start)

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

73% typ.

Switching Frequency

UL60950-1 TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-10°C to +60°C (See Derate Curve)

Storage Temperature

-20°C to +85°C, 10~95% RH

Relative Humidity

20 to +90% RH

MTBF

160.6K Hrs min, MIL-HDBK-217F (25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 light industry level, criteria A

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Size (mm)

215 x 115 x 50mm

Size (Inches)

8.46” x 4.53” x 1.97”

Weight (g)

1200g

Weight (oz)

42.33oz

Output Specifications

Physical Specifications

Output Voltage

5 Volts(DC)/12 Volts(DC)/24 Volts(DC)/-12 Volts(DC)

Output Amps

15 Amps/4.0 Amps/3.0 Amps/0.7 Amps

Load Regulation

±2.0%/±2.0%/±6.0%/±2.0%

Line Regulation

±1.0%/±1.0%/±2.0%/±1.0%

Temperature Coefficient

±0.03% / °C (0-50°C)

Ripple and Noise

100mVpk-pk/150mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1)

Over Voltage Protection

5Volts(DC): 5.75~6.75Volts(DC), 3.3Volts(DC): 3.8~4.4Volts(DC), QP-150D: 12Volts(DC): 13.8~16.2Volts(DC), QP-150F: 17.25~20.25Volts(DC) Shutdown o/p voltage, re-power

Over Current Protection

105~150% rated output power, Constent Current limiting, auto recover

Over Temperature Protection

95°C±5°C (TSW1) detect of Q1,Q2, power transistor, Shutdown o/p voltage, re-power after cool down

DC Voltage Adjust (typ.)

5Volts(DC): 4.75~5.5Volts(DC), 3.3Volts(DC): 3.14~3.63Volts(DC), QP-200D(12Volts): 11.4~13.2Volts(DC), QP-200F(15Volts): 14.25~16.5Volts(DC)

Hold Up Time

24mS