100W Quad Output with PFC Function
QP100DRL 100w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
QP100-3A CH1 |
5V |
8A |
+/-2.0% |
±1%, |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
2~10A |
74% typ. |
|
QP100-3A CH2 |
3.3V |
8A |
+/-2.0% |
±1%, |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~10A |
74% typ. |
|
QP100-3A CH3 |
12V |
1.3A |
+/-6.0% |
+/-2.0% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0.3~3A |
74% typ. |
||
|
QP100-3A CH4 |
-5V |
0.6A |
+/-2.0% |
±1%, |
150mVp-p max. (Note 2) |
+/-5.0% (Note 3) |
0~1A |
74% typ. |
||
|
QP100-3B CH1 |
5V |
8A |
+/-2.0% |
±1%, |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
2~10A |
74% typ. |
|
QP100-3B CH2 |
3.3V |
2.4A |
+/-2.0% |
±1%, |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~10A |
74% typ. |
|
QP100-3B CH3 |
12V |
1A |
+/-6.0% |
+/-2.0% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0.3~3A |
74% typ. |
||
|
QP100-3B CH4 |
-12v |
0.6A |
+/-2.0% |
±1%, |
150mVp-p max. (Note 2) |
+/-5.0% (Note 3) |
0~1A |
74% typ. |
||
|
QP100-3C CH1 |
5V |
3A |
+/-2.0% |
±1%, |
100mVp-p max. (Note 2) |
5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
4.75~ 5.5V |
2~10A |
75% typ. |
|
QP100-3C CH2 |
3.3V |
2A |
+/-2.0% |
±1%, |
100mVp-p max. (Note 2) |
3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover |
+/- 3.0% (Note 3) |
3.14~ 3.63V |
0~10A |
75% typ. |
|
QP100-3C CH3 |
15V |
1A |
+/-6.0% |
+/-2.0% |
150mVp-p max. (Note 2) |
+/-6.0% (Note 3) |
0.3~3A |
75% typ. |
||
|
QP100-3C CH4 |
-15V |
0.6A |
+/-2.0% |
±1%, |
150mVp-p max. (Note 2) |
+/-5.0% (Note 3) |
0~1A |
75% typ. |
|
Universal AC input/Full range |
|
|
Built-in active PFC function, PF>0.95 |
|
|
Protections; Short circuit / Over load/ Over voltage |
|
|
Free air cooling convection |
|
|
CH4± Polarity is selectable |
|
|
Fixed switching frequency at 100KHz(optional) |
QP100/DRL series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications Physical Specifications
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature. 2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||