QP100DRL 100w Power Supplies

100W Quad Output with PFC Function

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

QP100-3A CH1

5V

8A

+/-2.0%

±1%,

100mVp-p max. (Note 2)

5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover

+/- 3.0% (Note 3)

4.75~ 5.5V

2~10A

74% typ.

QP100-3A CH2

3.3V

8A

+/-2.0%

±1%,

100mVp-p max. (Note 2)

3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover

+/- 3.0% (Note 3)

3.14~ 3.63V

0~10A

74% typ.

QP100-3A CH3

12V

1.3A

+/-6.0%

+/-2.0%

150mVp-p max. (Note 2)

+/-6.0% (Note 3)

0.3~3A

74% typ.

QP100-3A CH4

-5V

0.6A

+/-2.0%

±1%,

150mVp-p max. (Note 2)

+/-5.0% (Note 3)

0~1A

74% typ.

QP100-3B CH1

5V

8A

+/-2.0%

±1%,

100mVp-p max. (Note 2)

5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover

+/- 3.0% (Note 3)

4.75~ 5.5V

2~10A

74% typ.

QP100-3B CH2

3.3V

2.4A

+/-2.0%

±1%,

100mVp-p max. (Note 2)

3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover

+/- 3.0% (Note 3)

3.14~ 3.63V

0~10A

74% typ.

QP100-3B CH3

12V

1A

+/-6.0%

+/-2.0%

150mVp-p max. (Note 2)

+/-6.0% (Note 3)

0.3~3A

74% typ.

QP100-3B CH4

-12v

0.6A

+/-2.0%

±1%,

150mVp-p max. (Note 2)

+/-5.0% (Note 3)

0~1A

74% typ.

QP100-3C CH1

5V

3A

+/-2.0%

±1%,

100mVp-p max. (Note 2)

5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover

+/- 3.0% (Note 3)

4.75~ 5.5V

2~10A

75% typ.

QP100-3C CH2

3.3V

2A

+/-2.0%

±1%,

100mVp-p max. (Note 2)

3.8~4.4V, Protection type: Shut down o/p voltage, re-power on to recover

+/- 3.0% (Note 3)

3.14~ 3.63V

0~10A

75% typ.

QP100-3C CH3

15V

1A

+/-6.0%

+/-2.0%

150mVp-p max. (Note 2)

+/-6.0% (Note 3)

0.3~3A

75% typ.

QP100-3C CH4

-15V

0.6A

+/-2.0%

±1%,

150mVp-p max. (Note 2)

+/-5.0% (Note 3)

0~1A

75% typ.

Universal AC input/Full range

Built-in active PFC function, PF>0.95

Protections; Short circuit / Over load/ Over voltage

Free air cooling convection

CH4± Polarity is selectable

Fixed switching frequency at 100KHz(optional)

QP100/DRL series

Input Specifications

Input Voltage Range

90~264VAC 127~370VDC (Note 5)

Frequency Range

47 ~ 63Hz

Inrush Current

Cold Start ? 40A/230V typ.

Input Current

1.5A/115VAC, 0.75A/230VAC typ.

Leakage Current

<3.5mA/240VAC

Power Factor Correction

PF>0.95/230VAC PF>0.98/115VAC at full load typ.

General Specifications

Isolation

3KVAC (Note 4)

Isolation Input-Ground

1.5KVAC (Note 4)

Isolation Output-Ground

0.5KVAC (Note 4)

Insulation Resistance

100M Ohms/500VDC (Note 4)

Efficiency

74% typ.

Safety Approvals

UL60950-1 TUV EN60950-1 approved (Note 4)

Harmonic Current

Compliance to EN61000-3-2,-3 (Note 4)

Environmental Specifications

Operating Temperature

-10°C to +60°C (Refer to outlput load derating curve)

Storage Temperature

-20°C to +85°C

Working Humidity

20 to +90% RH non cond

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN 55022 (CISPR22) Class B (Note 4)

MTBF

139.9K hrs min. MIL0HDBK-217F (25°C)

Vibration

10 ~ 500Hz. 2G 10- min./1 cycle, 60min. Each along X, Y, Z axes

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A (Note 4)

Output Specifications

Physical Specifications

Size (mm)

199x99x50mm

Weight (g)

0.87Kg; 20pcs/18.4Kg/1.28CUFT

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °C of ambient temperature.

2. Ripple and noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equpiment must be re-confirmed that it still meets EMC directives.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

5V

Output Amps

8A

Load Regulation

±2.0%

Line Regulation

±1%,

Temperature Coefficient

±0.03%/°C (0~50°C)

Ripple and Noise

100mVp-p max. (Note 2)

Over Voltage Protection

5.75~6.75V, Protection type: Shut down o/p voltage, re-power on to recover

Over Current Protection

105 ~ 150% rated output power, Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over Temperature Protection

95°C ±5% (TSW1), Protection type: Shutdown o/p voltage, recovers automatically after temperature goes down

Voltage Tolerance

± 3.0% (Note 3)

DC Voltage Adjust

4.75~5.5V

Minimum Load Requirement

2~10A

Rise Time

800ms, 50ms/230VAC 80050ms/115VAC

Hold Up Time

24ms/230VAC 24ms/115VAC at full load typ.