Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PV15 15 Watt Switch Mode Power Supplies

Compact 15 Watt Enclosed Switching Power Supplies

Universal 90-264VAC Input

Compact Footprint

High Efficiency

Regulated Outputs

3000V Isolation

Built in EMI Filter

Model Number

Output Voltage

Output Amps

Ripple and Noise

Efficiency

PV15-5S

5 VDC

3A

80mV

0.77

PV15-12S

12 VDC

1.25A

120mV

0.8

PV15-15S

15 VDC

1A

120mV

0.8

PV15-24S

24 VDC

0.63A

120mV

0.8

PV15-48S

48 VDC

0.32A

120mV

0.8

PV15 series

Input Specifications

Input Voltage Range

90-264 VAC / 125-370 VDC

Frequency Range

47-63Hz

Inrush Current

20A @ 120VAC Input *, 40A @ 220VAC Input *

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

77%

Efficiency

65Khz, (fixed, typical)

Switching Frequency

UL60950-1, EN60950-1

Environmental Specifications

Operating Temperature

-20 to +70°C (See Derate)

EMC

EN55022 Class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,1, ENV50204

Storage Temperature

-20 to +85°C *

Relative Humidity

0% to +95%, non-cond *

EMI

Compliance to EN55022B(CISPR22B)

Output Specifications

Output Voltage

5 VDC

Output Amps

3A

Load Regulation

± 0.5%, typ.; 1% max. (20% to 100%)

Line Regulation

± 0.5%, typ.; 1% max.

Preset Accuracy

1%, typ

Ripple and Noise

80mV

Over Voltage Protection

Clamp *

Short Circuit Protection

Latching, recoverable after cooling and re-power

DC Voltage Adjust (typ.)

± 10% (typ)

Hold Up Time

16mS, typ (Nom I/P, FL)

Physical Specifications

* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Size (mm)

66 x 50.4 x 28mm

Size (Inches)

2.59” x 1.98” x 1.1”

Construction

Enclosed

Weight (g)

125g

Weight (oz)

4.4oz

Notes