Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PSP600 600 Watt Enclosed Power Supplies

600W with PFC and Parallel Function

Universal AC input

Protections:Short circuit/Over load/Over voltage/Over temperature

Built-in active PFC function

Foced air cooling by built-in DC fan

Current sharing up to 2000W(3+1)

With DC OK Signal output

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

Over Temperature Protection

DC Voltage Adjust (typ.)

Efficiency

PSP600-5 5 Volts (DC) 80A

±1.0%

180mVpk-pk (Note 1)

5.75~6.75Volt(DC) Shutdown o/p voltage, re-power

95°C(TSW1) detect on heatsink of power transitor; 95°C(TSW51) detect on heatsink of power diode, shutdown o/p voltage, re-power after cool down

4.75~ 5.5Volt (DC)

0.79

PSP600-12 12 Volts (DC) 50A

±0.5%

240mVpk-pk (Note 1)

13.8~16.2Volt(DC) Shutdown o/p voltage, re-power

85°C(TSW1) detect on heatsink of power transitor; 80°C(TSW51) detect on heatsink of power diode shutdown o/p voltage, re-power after cool down

10~ 13.2Volt (DC)

0.84

PSP600-13.5 13.5 Volts (DC) 44.5A

±0.5%

240mVpk-pk (Note 1)

15.5~18.2Volt(DC) Shutdown o/p voltage, re-power

85°C(TSW1) detect on heatsink of power transitor; 80°C(TSW51) detect on heatsink of power diode shutdown o/p voltage, re-power after cool down

12~ 15Volt (DC)

0.85

PSP600-15 15 Volts (DC) 40A

±0.5%

240mVpk-pk (Note 1)

18~21Volt(DC) Shutdown o/p voltage, re-power

85°C(TSW1) detect on heatsink of power transitor; 80°C(TSW51) detect on heatsink of power diode shutdown o/p voltage, re-power after cool down

13.5~ 18Volt (DC)

0.85

PSP600-24 24 Volts (DC) 25A

±0.5%

240mVpk-pk (Note 1)

27.6~32.4Volt(DC) Shutdown o/p voltage, re-power

85°C(TSW1) detect on heatsink of power transitor; 80°C(TSW51) detect on heatsink of power diode shutdown o/p voltage, re-power after cool down

20~ 26.4Volt (DC)

0.86

PSP600-27 27 Volts (DC) 22.2A

±0.5%

240mVpk-pk (Note 1)

31~36.5Volt(DC) Shutdown o/p voltage, re-power

85°C(TSW1) detect on heatsink of power transitor; 80°C(TSW51) detect on heatsink of power diode shutdown o/p voltage, re-power after cool down

24~ 30Volt (DC)

0.86

PSP600-48 48 Volts (DC) 12.5A

±0.5%

300mVpk-pk (Note 1)

57.6~67.2Volt(DC) Shutdown o/p voltage, re-power

85°C(TSW1) detect on heatsink of power transitor; 80°C(TSW51) detect on heatsink of power diode shutdown o/p voltage, re-power after cool down

41~56Volt (DC)

0.87

PSP600 series

600W with PFC and Parallel Function

Input Specifications

Input Voltage Range

90 ~ 264VAC 124~370vdc (Note 3)

Input Reflected Ripple Current

6.8 Amps@115VAC, 3.4 Amps@230VAC

Frequency Range

47-63Hz

Inrush Current

20Amps/115VAC; 40Amps/230VAC (cold start)

General Specifications

Isolation

4242VDC

Isolation Input-Ground

2121VDC

Isolation Output-Ground

707VDC

Insulation Resistance

79%

Switching Frequency

UL60950-1, TUV EN60950-1 Approved

Environmental Specifications

Operating Temperature

-20°C to +60°C (See Derate Curve)

Storage Temperature

-40°C to +85°C, 10~95% RH

Relative Humidity

20~90% RH, non cond

MTBF

116.4KHrs min,MIL-HDBK-217F(25°C)

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, light Industry Level, Criteria A

Output Specifications

Output Voltage

5vdc

Output Amps

80A

Load Regulation

±1.0%

Line Regulation

±0.5%

Temperature Coefficient

±0.03% / °C (0-50°C)

Ripple and Noise

180mVpk-pk (Note 1)

Over Voltage Protection

5.75~6.75Volt(DC) Shutdown o/p voltage, re-power

Over Current Protection

105~135% rated output power, Constant Current limiting, auto-recov

Over Temperature Protection

95°C(TSW1) detect on heatsink of power transitor; 95°C(TSW51) detect on heatsink of power diode, shutdown o/p voltage, re-power after cool down

DC Voltage Adjust (typ.)

4.75~5.5Volt(DC)

Hold Up Time

20mS

Remore Shutdown

RC+/RC-: Short=Power ON Open=Power Off

Physical Specifications

Size (mm)

170 x 120 x 93 mm

Size (Inches)

6.69”x 4.72”x 3.66”

Weight (g)

1900g

Weight (oz)

67.02oz

Notes

1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.