PSP1500 1500 Watt Enclosed Power Supplies
|
AC input active surge current limiting |
|
|
Protections:Short circuit/Over load/Over voltage/Over temperature |
|
|
Built-in active PFC function |
|
|
Built-in constant current limiting circuit |
|
|
Built-in remote ON-OFF control |
|
|
Built-in remote sense function |
|
Model Number |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
| PSP1500-5 | 5vdc | 217.5A |
±2.0% |
±0.5% |
100mVpk-pk |
5.75~6.75Volt(DC) Shutdown o/p voltage, re-power |
4.75~5.5Volt(DC) |
0.77 |
| PSP1500-12 | 12vdc | 112.5A |
±0.5% |
±0.3% |
150mVpk-pk |
13.8~16.2Volt(DC) Shutdown o/p voltage, re-power |
10~13.2Volt(DC) |
0.84 |
| PSP1500-13.5 | 13.5vdc | 100.5A |
±0.5% |
±0.3% |
150mVpk-pk |
15.5~18.2Volt(DC) Shutdown o/p voltage, re-power |
12~15Volt(DC) |
0.84 |
| PSP1500-15 | 15vdc | 90A |
±0.5% |
±0.3% |
150mVpk-pk |
18~21Volt(DC) Shutdown o/p voltage, re-power |
13.5~18Volt(DC) |
0.84 |
| PSP1500-24 | 24vdc | 56.4A |
±0.5% |
±0.2% |
150mVpk-pk |
27.6~32.4Volt(DC) Shutdown o/p voltage, re-power |
20~26.4Volt(DC) |
0.85 |
| PSP1500-27 | 27vdc | 50.4A |
±0.5% |
±0.2% |
150mVpk-pk |
31~36.5Volt(DC) Shutdown o/p voltage, re-power |
24~30Volt(DC) |
0.85 |
| PSP1500-48 | 48vdc | 28.5A |
±0.5% |
±0.2% |
200mVpk-pk |
57.6~67.2Volt(DC) Shutdown o/p voltage, re-power |
41~56Volt(DC) |
0.86 |
PSP1500 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |