Universal AC input |
|
|
Protections:Short circuit/Over load/Over voltage/Over temperarure |
|
|
Low leakage current <0.5mA |
|
|
Cooling by free air convention |
|
|
Low cost |
|
|
Fixed switching frequency at 100KHz |
PS25 25 Watt Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Line Regulation |
Ripple and Noise |
Voltage Tolerance |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
| PS25-3.3 | 3.3vdc | 5 Amps |
0~ 5Amps |
±2.5% |
±0.5% |
80mVpk-pk (note 1) |
3.0% (note 2) |
3.8 ~ 4.46Volt(DC) Shut down o/p voltage,re-power |
3.14~ 3.63Volt(DC) |
66% |
| PS25-5 | 5vdc | 5 Amps |
0~ 5Amps |
±2.0% |
±0.5% |
80mVpk-pk (note 1) |
2.0% (note 2) |
5.75 ~ 6.75Volt(DC) Shut down o/p voltage,re-power |
4.75~ 5.5Volt(DC) |
74% |
| PS25-7.5 | 7.5vdc | 3.3 Amps |
0~ 3.3Amps |
±2.0% |
±0.5% |
80mVpk-pk (note 1) |
2.0% (note 2) |
8.6 ~ 10.1Volt(DC) Shut down o/p voltage,re-power |
6.0~ 9.0Volt(DC) |
76% |
| PS25-12 | 12vdc | 2.1 Amps |
0~ 2.1Amps |
±1.0% |
±0.3% |
100mVpk-pk (note 1) |
2.0% (note 2) |
13.8 ~ 16.2Volt(DC) Shut down o/p voltage,re-power |
10~ 13.2Volt(DC) |
78% |
| PS25-13.5 | 13.5vdc | 1.9 Amps |
0~ 1.9Amps |
±1.0% |
±0.3% |
100mVpk-pk (note 1) |
2.0% (note 2) |
15.5 ~ 18.2Volt(DC) Shut down o/p voltage,re-power |
12~ 15Volt(DC) |
78% |
| PS25-15 | 15vdc | 1.7 Amps |
0~ 1.7Amps |
±1.0% |
±0.3% |
100mVpk-pk (note 1) |
2.0% (note 2) |
17.3 ~ 20.3Volt(DC) Shut down o/p voltage,re-power |
13.5~ 18Volt(DC) |
78% |
| PS25-24 | 24vdc | 1.0 Amps |
0~ 1.0Amps |
±0.5% |
±0.2% |
240mVpk-pk (note 1) |
2.0% (note 2) |
27.6 ~ 32.4Volt(DC) Shut down o/p voltage,re-power |
20~ 26.4Volt(DC) |
79% |
| PS25-27 | 27vdc | 0.9 Amps |
0~ 0.9Amps |
±0.5% |
±0.2% |
240mVpk-pk (note 1) |
2.0% (note 2) |
31~ 36.5Volt(DC) Shut down o/p voltage,re-power |
26~ 31.5Volt(DC) |
79% |
| PS25-48 | 48vdc | 0.5 Amps |
0~ 0.5Amps |
±0.5% |
±0.2% |
350mVpk-pk (note 1) |
2.0% (note 2) |
55.2~ 64.8Volt(DC) Shut down o/p voltage,re-power |
41~ 56Volt(DC) |
79% |
PS25 series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |