Universal AC input |
|
|
Built-in active PFC function, PF>0.95 |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
Cooling by free air convection |
|
|
Fixed switching frequency at 45KHz |
|
|
With power good signal output(Optional) |
PQ100 100w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Ripple and Noise |
Voltage Tolerance |
Line Regulation |
Efficiency |
|
5 Volts(DC)/12 Volts(DC)/-5 Volts(DC)/-12 Volts(DC) |
10 Amps/3.5 Amps/0.5 Amps/0.5 Amps |
2~10Amps/0.5~4.5Amps/0~1.0Amps/0~1.0Amps |
±2.0%/±5.0%/ ±1.0%/±1.0% |
80mVpk-pk/250mVpk-pk/80mVpk-pk/120mVpk-pk (note 1) |
±3.0%/±12%/ ±6.0%/±6.0% (note 2) |
±1.0%/±5.0%/ ±1.0%/±1.0% |
72% |
|
|
5 Volts(DC)/15 Volts(DC)/-5 Volts(DC)/-15 Volts(DC) |
8.0 Amps/3.5 Amps/0.5 Amps/0.5 Amps |
2.0~8.0Amps/0.5~4.0Amps/0~1.0Amps/0~1.0Amps |
±1.0%/±5.0%/ ±1.0%/±1.0% |
80mVpk-pk/150mVpk-pk/80mVpk-pk/150mVpk-pk (note 1) |
±2.0%/±6.0%/ ±6.0%/±6.0% (note 2) |
±1.0%/±3.0%/ ±1.0%/±1.0% |
74% |
|
|
5 Volts(DC)/12 Volts(DC)/24 Volts(DC)/-12 Volts(DC) |
5.0 Amps/2.0 Amps/2.0 Amps/0.5 Amps |
2.0~5.0Amps/0.5~4.5Amps/0.4~2.0Amps/0~1.0Amps |
±1.0%/±5.0%/ ±5.0%/±1.0% |
80mVpk-pk/120mVpk-pk/180mVpk-pk/120mVpk-pk (note 1) |
±2.0%/±6.0%/ ±10%/±6.0% (note 2) |
±1.0%/±3.0%/ ±1.0%/±1.0% |
77% |
|
|
5 Volts(DC)/12 Volts(DC)/15 Volts(DC)/24 Volts(DC) |
8.0 Amps/3.0 Amps/0.6 Amps/0.6 Amps |
2.0~8.0Amps/0.5~3.0Amps/0~1.0Amps/0~1.0Amps |
±1.0%/±5.0%/ ±1.0%/±1.0% |
80mVpk-pk/120mVpk-pk/150mVpk-pk/120mVpk-pk (note 1) |
±2.0%/±6.0%/ ±6.0%/±6.0% (note 2) |
±1.0%/±3.0%/ ±1.0%/±1.0% |
74% |
PQ100 series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |