Universal AC input |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
Built-in active PFC function |
|
|
PWM control and regulated |
|
|
High power density 6.117W/cubic inch |
|
|
Built-in remote sense function |
PPS125 125w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Ripple and Noise |
Voltage Tolerance |
Over Voltage Protection |
DC Voltage Adjust (typ.) |
Efficiency |
|
PPT-125-3.3 |
3.3 Volts(DC) |
20 Amps |
0~20Amps (Convection), 0~25Amps (18CFM FAN) |
100mVpk-pk (note 1) |
±0.2% (note 2) |
3.63~4.45Volts(DC) Hiccup mode, auto recover |
3.13~ 3.46Volts(DC) |
70% |
|
PPT-125-5 |
5 Volts(DC) |
20 Amps |
0~20Amps (Convection), 0~25Amps (18CFM FAN) |
100mVpk-pk (note 1) |
±0.2% (note 2) |
5.5~6.75Volts(DC) Hiccup mode, auto recover |
4.75~ 5.25Volts(DC) |
79% |
|
PPT-125-12 |
12 Volts(DC) |
8.5 Amps |
0~8.5Amps (Convection), 0~10.5Amps (18CFM FAN) |
100mVpk-pk (note 1) |
±0.2% (note 2) |
13.8~16.2Volts(DC) Hiccup mode, auto recover |
11.40~ 12.60Volts(DC) |
80% |
|
PPT-125-13.5 |
13.5 Volts(DC) |
7.5 Amps |
0~7.5Amps (Convection), 0~9.3Amps (18CFM FAN) |
100mVpk-pk (note 1) |
±0.2% (note 2) |
15.5~20.25Volts(DC) Hiccup mode, auto recover |
12.82~ 14.17Volts(DC) |
80% |
|
PPT-125-15 |
15 Volts(DC) |
6.7 Amps |
0~6.7Amps (Convection), 0~8.4Amps (18CFM FAN) |
100mVpk-pk (note 1) |
±0.2% (note 2) |
17.25~20.25Volts(DC) Hiccup mode, auto recover |
14.25~ 15.75Volts(DC) |
80% |
|
PPT-125-24 |
24 Volts(DC) |
4.2Amps |
0~4.2Amps (Convection), 0~5.2Amps (18CFM FAN) |
150mVpk-pk (note 1) |
±1.0% (note 2) |
27.6~32.4Volts(DC) Hiccup mode, auto recover |
22.80~ 25.20Volts(DC) |
83% |
|
PPT-125-27 |
27 Volts(DC) |
3.8 Amps |
0~3.8Amps (Convection), 0~4.6Amps (18CFM FAN) |
150mVpk-pk (note 1) |
±1.0% (note 2) |
31.05~36.45Volts(DC) Hiccup mode, auto recover |
25.65~ 28.35Volts(DC) |
83% |
|
PPT-125-48 |
48 Volts(DC) |
2.1 Amps |
0~2.1Amps (Convection), 0~2.6Amps (18CFM FAN) |
250mVpk-pk (note 1) |
±1.0% (note 2) |
57.6~67.2Volts(DC) Hiccup mode, auto recover |
45.60~ 50.40Volts(DC) |
84% |
PPS-125 series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |