|
Universal AC input |
|
|
Built-in active PFC function, PF>0.95 |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
Cooling by free air convection |
|
|
Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional) |
PPQ1003 1003 Watt Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Voltage Tolerance |
|
3.3vdc/5vdc/12vdc/-5vdc |
10 Amps/10 Amps/2.0 Amps/0.3 Amps |
100mVpk-pk/100mVpk-pk/150mVpk-pk/100mVpk-pk (Note 1) |
±3.0%/±3.0%/±6.0%/±6.0% (Note 2) |
|
|
3.3vdc/5vdc/12vdc/-12vdc |
10 Amps/10 Amps/2.0 Amps/0.3 Amps |
100mVpk-pk/100mVpk-pk/150mVpk-pk/120mVpk-pk (Note 1) |
±3.0%/±3.0%/±6.0%/±6.0% (Note 2) |
|
|
3.3vdc/5vdc/15vdc/-15vdc |
10 Amps/10 Amps/1.5 Amps/0.3 Amps |
100mVpk-pk/100mVpk-pk/180mVpk-pk/150mVpk-pk (Note 1) |
±3.0%/±3.0%/+10,-5%/±6.0% (Note 2) |
|
|
3.3vdc/5vdc/12vdc/24vdc |
10 Amps/10 Amps/2.0 Amps/0.3 Amps |
100mVpk-pk/100mVpk-pk/150mVpk-pk/150mVpk-pk (Note 1) |
±3.0%/±3.0%/±6.0%/±6.0% (Note 2) |
PPQ1003 series
|
Environmental Specifications
Input Specifications
General Specifications |
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |
