Single Outputs |
|
|
Universal 90-264VAC Input |
|
|
5VDC to 48VDC Output Isolation |
|
|
5656VDC Input to Output Isolation |
|
|
Active Power Factor Correction |
PMMK450S 450w Power Supplies
|
Model Number |
Power Factor Correction |
Output Voltage |
Output Amps |
Load Regulation |
Line Regulation |
Ripple and Noise |
Efficiency |
|
PMMK450S-5 U,E |
0.95min / IEC61000-3-2 |
5VDC |
60 Amps |
0.5% / 3% |
0.4% / ±1.0% |
50mV pk-pk |
76% / 80% |
|
PMMK450S-12 U,E |
0.95min / IEC61000-3-3 |
12 VDC |
37.5 Amps |
0.3% / 1% |
0.3% / ±1.0% |
120mV pk-pk |
77% / 85% |
|
PMMK450S-24 U,E |
0.95min / IEC61000-3-4 |
24 VDC |
18.75 Amps |
0.2% / 0.5% |
0.2% / ±0.5% |
240mV pk-pk |
78% / 86% |
|
PMMK450S-36 U,E |
0.95min / IEC61000-3-5 |
36 VDC |
12.5 Amps |
0.1% / 0.5% |
0.1% / ±0.5% |
360mV pk-pk |
79% / 86% |
|
PMMK450S-48 U,E |
0.95min / IEC61000-3-6 |
48 VDC |
9.375 Amps |
0.1% / 0.5% |
0.1% / ±0.5% |
480mV pk-pk |
81% / 88% |
PMMK450S series
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |