Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PMMK225D 225w Switch Mode Power Supplies

PMMK225D 225w  Switch Mode Power Supplies

225 Watt DIN Rail Mountable Switching Power Supply with PFC

225 Watts Output power

Single Outputs

Universal 90-264VAC Input

4242VDC Input to Output Isolation

Active Power Factor Correction

Model Number

Output Voltage

Output Amps

Ripple and Noise

Efficiency

PMMK225S-5D

5 VDC

40

100mV pk-pk (Notes 1, 4)

75% FL. Nom I/P

PMMK225S-12D

12 VDC

18.8

120mV pk-pk (Notes 1, 4)

82% FL. Nom I/P

PMMK225S-15D

15 VDC

15

150mV pk-pk (Notes 1, 4)

83% FL. Nom I/P

PMMK225S-24D

24 VDC

9.4

240mV pk-pk (Notes 1, 4)

84% FL. Nom I/P

PMMK225S-36D

36 VDC

6.25

360mV pk-pk (Notes 1, 4)

84% FL. Nom I/P

PMMK225S-48D

48 VDC

4.7

480mV pk-pk (Notes 1, 4)

84% FL. Nom I/P

PMMK225D series

Input Voltage Range

90-264 VAC (100-240VAC Nom.)

Frequency Range

47 ~ 63Hz

Inrush Current

30A @ 115VAC Cold Start, FL* 60A @ 230VAC Cold Start, FL* typ.

Input Current

3.8 Amps max., 90V I/P 1.3Amps max, 264V I/P

Leakage Current

<0.2mA, 240Vin, 50Hz

Power Factor Correction

0.95, min. Nom I/P, FL

Input Specifications

General Specifications

Isolation

5656VDC (Note 2)

Isolation Input-Ground

2121VDC (Note 2)

Isolation Output-Ground

707VDC (Note 2)

Insulation Resistance

?20M?

Efficiency

75% FL. Nom I/P

Safety Approvals

UL/cUL60601-1, EN60601-1 (TUV), EN60601-1-2:2001 (CE), IEC60601-1 (CB)

Environmental Specifications

Operating Temperature

-20 to +70°C (See Derate Curve)

Storage Temperature

-25 to +85°C

Working Humidity

10% to +95%,

Storage Humidity

5-95%

EMI

EN55022 Class B

MTBF

100,000 Hrs, min Mil Std 217F, 25°C

Vibration

4G Peak, 50-500Hz, 3 Axes

EMS

Harmonics Class D, 61000-3-2 Fluctuations 61000-3-3 ESD 61000-4-2 RS 61000-4-3 EFT 61000-4-4 Surge 61000-4-5 CS 61000-4-6 DIPS 61000-4-11

Drop Test

70 CM

Size (Inches)

3.86”W x 7”L x 1.57”H

Weight (g)

703g

Weight (oz)

1.55 lb,

Construction

Enclosed

Output Specifications

Physical Specifications

Notes

1. All measurements should be made directly at the terminals of the power supply.

2. Isolation for up to 1 minute duration.

3. Preset Accuracy measured at nominal load, 120VAC input.

4. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF ceramic bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Voltage

5 VDC

Output Amps

40

Load Regulation

±1%, max. 10%-FL

Line Regulation

±1%, max. LL-HL

Ripple and Noise

100mV pk-pk (Notes 1, 4)

Over Voltage Protection

130% max. Auto Recovery

Over Current Protection

150% max. Auto Recovery

Short Circuit Protection

Auto Recover after fault condition is removed

Preset Accuracy

±1%, typ (2% 5 Vout) (Note 3)

Rise Time

<4S, <20mS, typ (Nom I/P, FL)

Hold Up Time

20mS, typ (Nom I/P, FL)

Over-Shoot

<10% of Nominal Output

Under-Shoot

<10% of Nominal Output

Remote Shutdown

Open Collector, Logic “1” = ON, “0” = Off. No Termination necessary to maintain constant “On” operation

Remote Sense

Compensates for up to 0.5V drop