Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PMK450U 450 Watt Power Supplies

450 Watts Output Power

Single Outputs

Universal 90-264VAC Input

5VDC to 48VDC Output Isolation

4242VDC Input to Output Isolation

Active Power Factor Correction

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

Efficiency

PMK450S-5U *(-CS) 5 VDC 60 Amps

0.5% / 3%

0.4% / ±1.0%

50mV pk-pk

76% / 80%

PMK450S-12U*(-CS) 12 VDC 37.5 Amps

0.3% / 1%

0.3% / ±1.0%

120mV pk-pk

77% / 85%

PMK450S-24U*(-CS) 24 VDC 18.75 Amps

0.2% / 0.5%

0.2% / ±0.5%

240mV pk-pk

78% / 86%

PMK450S-36U *(-CS) 36 VDC 12.5 Amps

0.1% / 0.5%

0.1% / ±0.5%

360mV pk-pk

79% / 86%

PMK450S-48U*(-CS) 48 VDC 9.375 Amps

0.1% / 0.5%

0.1% / ±0.5%

480mV pk-pk

81% / 88%

* The PMK450S Series power supplies are available with current-sharing (CS) option for N+1 paralleling and redundant power applications. To receive this option with your product simply add "-CS" to the end of the Model Number. For example PMK450S-5U-CS. Please see the Specification Sheet for instructions on how to utilize.

PMK450S Series

Input Specifications

Input Voltage Range

100 - 240VAC Nominal, 90-264VAC Maximal

Frequency Range

50 - 60 Hz

Inrush Current

30A at FL, 115VAC, 60A at FL, 230VAC (cold start)

Input Current

7A max at 90VAC 2.5A max at 264VAC

Leakage Current

Less than 0.3mA @ 240VAC, 50Hz

Power Factor Correction

0.95min / IEC61000-3-2

Environmental Specifications

Operating Temperature

0°C to 70°C (See Derate Curve)

Storage Temperature

-40°C to 85°C

Relative Humidity

0 to +95%, non-cond

EMI

CISPR EN55022 class B

MTBF

100,000 Hrs min. @25°C

Vibration

4G’S peak, 50~500Hz, 3 AXES

Voltage Fluctuation

61000-3-3

ESD

Contact 6KV 61000-4-2, Air 8KV 61000-4-2

Radiated Field

FR: 80MHz-2.5GHz 61000-4-3, Field Strength: 3V / M 61000-4-3

EFT

2KV on AC power line 61000-4-4

Surge

1KV (L-L) & 2KV (L-PE) 61000-4-5

Conducted RF

3V (EMF) 61000-4-6

Voltage Variations

95% 250Cy , 70% 25 Cy 61000-4-11 40% 5Cy , 5% 0.5Cy 61000-4-11

General Specifications

Isolation

4242VDC (60S max)

Isolation Input-Ground

2121 VDC (60S max)

Isolation Output-Ground

707VDC (60S max)

Insulation Resistance

? 20M?

Efficiency

76% / 80%

Safety Approvals

UL/C-UL UL60950-1, TUV EN60950-1, CE EN60601-1 EN60601-1-2 : 200,1 CB IEC 60950-1

Output Specifications

Output Voltage

5 VDC

Output Amps

60 Amps

Load Regulation

0.5% / 3%

Line Regulation

0.4% / ±1.0%

Ripple and Noise

50mV pk-pk

Over Voltage Protection

130% (max) Auto-recovery

Over Current Protection

150% (max) Auto-recovery

Start Up

< 4S

Short Circuit Protection

Auto-recovery

Hold Up Time

16mS at nominal input voltage range

Overshoot

Less than 10% of nominal output volt

Undershoot

Less than 10% of nominal output volt

Remote shutdown

(Note 1)

Remote Sense

0.5V drop. max

Physical Specifications

Size (mm)

203.2x 127x 38 mm (PMMK450S-xx-U/UD), 224.9x 127x 40 mm (PMMK450S-xx-E/ED)

Size (Inches)

8”x 5”x 1.5” (PMMK450S-xx-U/UD), 8.85”x 5”x 1.57” (PMMK450S-xx-E/ED)

Construction

U-Bracket (PMMK450S-xx-U/UD), Enclosed DIN Rail (PMMK450S-xx-E/ED)

Weight (g)

U-Bracket (PMMK450S-xx-U) 963g, U-Bracket with Din clip (PMMK450S-xx-UD) 982g, Enclosed with Fan (PMMK450S-xx-E) 1058g, Din-rail wih Fan (PMMK450-xx-ED) 1077g

Weight (oz)

U-Bracket (PMMK450S-xx-U) 33.91oz, U-Bracket with Din clip (PMMK450S-xx-UD) 34.85oz, Enclosed with Fan (PMMK450S-xx-E) 37.25oz, Din-rail wih Fan (PMMK450-xx-ED) 37.92oz

Notes

1. Open Collector, Logic “1”=On, “0”=Off. No termination with S/D pin to maintain constant “On” operation. * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.