320 Watt Medical Grade DIN Rail Mount Power Supply with PFC
PMK320D 320w Medical Power Supplies
|
320 Watts Output Power |
|
|
Universal 90-264VAC Input |
|
|
5VDC to 48VDC Outputs |
|
|
5656VDC Input to Output Isolation |
|
|
Can be installed on DIN rail TS35/7.5 or 15 |
|
|
Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Efficiency |
|
5 VDC |
60 |
100mV pk-pk (Notes 1 & 4) |
75% FL. Nom I/P |
|
|
12 VDC |
26.7 |
120mV pk-pk (Notes 1 & 4) |
81% FL. Nom I/P |
|
|
15 VDC |
21.4 |
150mV pk-pk (Notes 1 & 4) |
84% FL. Nom I/P |
|
|
24 VDC |
13.4 |
150mV pk-pk (Notes 1 & 4) |
84% FL. Nom I/P |
|
|
36 VDC |
8.9 |
150mV pk-pk (Notes 1 & 4) |
84% FL. Nom I/P |
|
|
48 VDC |
6.7 |
150mV pk-pk (Notes 1 & 4) |
84% FL. Nom I/P |
PMK320D series
|
Input Specifications General Specifications
Environmental Specifications
|
Output Specifications Physical Specifications
Notes 1. All measurements should be made directly at the terminals of the power supply. 2. Isolation for up to 1 minute duration. 3. Preset Accuracy measured at nominal load, 120VAC input. 4. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF ceramic bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
|