Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PMK150D 150w Power Supplies

150 Watt Enclosed with DIN Rail mount and PFC

150 Watts output power

Universal 90-264VAC Input

5VDC to 48VDC Outputs

3000VAC input to Output Isolation

Active power factor correction

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Ripple and Noise

PMK150S-5D

5 VDC (Note 6)

30

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMK150S-12D

12 VDC (Note 6)

12.5

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMK150S-15D

15 VDC (Note 6)

10

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMK150S-24D

24 VDC (Note 6)

6.3

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMK150S-48D

48 VDC (Note 6)

3.2

± 0.5%, 10%-FL typ. (Note 7)

±0.5% (Note 8)

100mV pk-pk (Notes 1, 3, 10)

PMK150D-AD

5/12 VDC (Note 6)

15/7

±3/5%, 10%-FL typ. (Note 7)

±0.5/1% (Note 8)

50/100mV pk-pk (Notes 1, 3, 10)

PMK150D-BD

5/24 VDC (Note 6)

15/3.5

±3/5%, 10%-FL typ. (Note 7)

±0.5/2% (Note 8)

50/200mV pk-pk (Notes 1, 3, 10)

PMK150D-CD

12/24 VDC (Note 6)

7/3.5

±3/5%, 10%-FL typ. (Note 7)

±1/2% (Note 8)

100/200mV pk-pk (Notes 1, 3, 10)

PMK150D-DD

12/48 VDC (Note 6)

7/1.5

±3/5%, 10%-FL typ. (Note 7)

±1/4% (Note 8)

100/400mV pk-pk (Notes 1, 3, 10)

PMK150D series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47 ~ 63Hz

Inrush Current

30A @ 115VAC 60A @ 230VAC

Power Factor Correction

0.96 to 0.98

Isolation

3000VAC (Note 4)

Isolation Input-Ground

2000VAC (Note 4)

Isolation Output-Ground

500VAC (Note 4)

Switching Frequency

67KHz (fixed, typical)

Efficiency

75% min.

Safety Approvals

UL,TUV, CB, CE

General Specifications

Environmental Specifications

Operating Temperature

-10 to +70°C (See Derate Curve)

Storage Temperature

-25 to +85°C

Working Humidity

0% to +95%, non-cond *

MTBF

270,000 Hrs Mil Std 217, 25°C

EMS

EN55011 Class B

Output Voltage

5 VDC (Note 6)

Output Amps

30

Load Regulation

± 0.5%, 10%-FL typ. (Note 7)

Line Regulation

±0.5% (Note 8)

Temperature Coefficient

±0.05%/°C

Ripple and Noise

100mV pk-pk (Notes 1, 3, 10)

Over Voltage Protection

Latching, Auto Recover after fault condition is removed

Short Circuit Protection

Latching, Auto Recover after fault condition is removed

DC Voltage Adjust

±6%, typ

Preset Accuracy

±1%, typ (Note 9)

Hold Up Time

20mS, typ (Nom I/P, FL)

Physical Specifications

Notes

1. All measurements should be made directly at the terminals of the power supply.

2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load.

3. Ripple and noise dependent upon output voltage as specified per particular model.

4. Isolation for up to 1 minute duration.

5. Specified for free air convection cooling.

6. Minimum load is not required for proper operation.

7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load.

8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start.

9. Preset Accuracy measured at nominal load, 120VAC input.

10. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

Output Specifications

Size (Inches)

3.2” x 5.5” x 1.6”

Weight (g)

635g

Weight (oz)

1.4 lb,

Construction

Enclosed DIN Rail