Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

PMK130S 130 Watt Power Supplies

PMK130S 130 Watt  Power Supplies

130 Watts Output Power

Single Outputs

Universal 90-264VAC Input

5VDC to 48VDC Outputs

4646VDC Input to Output Isolation

Active Power Factor Correction

Single Output

Model Number

Output Voltage

Output Amps

Ripple and Noise

Efficiency

Capacitive Load

PMK130S-5

PMK130S-5-A

PMK130S-5U

PMK130S-5U-A

5 VDC

22 Amps

100mV pk-pk

75% / 80%

10,000uF

PMK130S-12

PMK130S-12-A

PMK130S-12U

PMK130S-12U-A

12 VDC

10.8 Amps

120mV pk-pk

80% / 82%

26,800uF

PMK130S-15

PMK130S-15-A

PMK130S-15U

PMK130S-15U-A

15 VDC

8.7 Amps

120mV pk-pk

80% / 85%

22,000uF

PMK130S-24

PMK130S-24-A

PMK130S-24U

PMK130S-24U-A

24 VDC

5.4 Amps

120mV pk-pk

82% / 85%

28,000uF

PMK130S-28

PMK130S-28-A

PMK130S-28U

PMK130S-28U-A

28 VDC

4.6 Amps

120mV pk-pk

82% / 85%

16,800uF

PMK130S-36

PMK130S-36-A

PMK130S-36U

PMK130S-36U-A

36 VDC

3.6 Amps

120mV pk-pk

82% / 85%

1,950uF

PMK130S-48

PMK130S-48-A

PMK130S-48U

PMK130S-48U-A

48 VDC

2.7 Amps

120mV pk-pk

82% / 85%

7,800uF

Triple Output

Model Number

Output Voltage

Output Amps

Ripple and Noise

Efficiency

Capacitive Load

PMK130T-A

PMK130T-A-A

PMK130T-AU

PMK130T-AU-A

5/12/-12 VDC

15/5/1 Amps

100/120/120mV pk-pk

75% / 80%

25,000uF

PMK130T-B

PMK130S-B-A

PMK130S-BU

PMK130S-BU-A

5/15/-15 VDC

15/5/1 Amps

100/150/150mV pk-pk

75% / 80%

25,000uF

PMK130T-C

PMK130S-C-A

PMK130S-CU

PMK130S-CU-A

5/24/12 VDC

4/4/2 Amps

100/240/120mV pk-pk

75% / 80%

25,000uF

PMK130T-D

PMK130T-D-A

PMK130T-DU

PMK130T-DU-A

12/24/5 VDC 8/2/3 Amps 12/240/1000mV pk-pk 75% / 80% 15,000uF

Note:

1. The PMK130 Series is offered in an optional U-Channel Chassis as well as with optional 3.96mm pitch 5 and 10 Pin Input and Output connectors (open frame construction and screw termainals are standard respectively). Simply add a "U" at the end of the Model Number to receive the U-Channel configuration or a "-A" to receive the pins, or both if both are desired. For example: The Model Number "PMK130T-AU-A" represents a triple output (5/12/-12VDC) U-Channel supply with 3.96 pitched pins (5 Input; 10 Output). See the Mechanical Dimensions on the Specification Sheet.

2. PMMK130T-A and all "U" options are not covered by UL Certification unless provided with more than 10 CFM forced air cooling applied 6-10cm above T1.

3. Derating curves acceptable up to 40°C for UL certified products.

PMK130S series

Input Specifications

Input Voltage Range

90-264VAC

Frequency Range

47 - 63 Hz

Inrush Current

30A @ 115VAC Input, 60A @ 230VAC Input

Input Current

7A max at 90VAC 2.5A max at 264VAC

Power Factor Correction

PF > 0.96 @ 230VAC, PF > 0.98 @ 115VAC (cold start)

Environmental Specifications

Operating Temperature

-10°C to +70°C (See Derate Curve)

EMC

EN55011, Class B

Storage Temperature

-25°C to +85°C

EMI

CISPR EN55022 class B

General Specifications

Isolation

4646VDC (note 3)

Isolation Input-Ground

2828 VDC (note 3)

Isolation Output-Ground

707VDC (note 3)

Insulation Resistance

≥ 20M Ω

Efficiency

75% / 80%

Switching Frequency

40 KHz (typ)

Safety Approvals

UL60950-1

Output Specifications

Output Voltage

5 VDC

Output Amps

22 Amps

Load Regulation

0.5% nom / 1% max (Notes 4,5)

Line Regulation

0.5% nom / 1% max (Notes 6)

Preset Accuracy

1%

Temperature Coefficient

0.05% / °C (0-50°C, typ)

Ripple and Noise

100mV pk-pk (Notes 1,2,8)

Over Voltage Protection

Latching, ecoverable after fault condition being removed.

Short Circuit Protection

Latching, ecoverable after fault condition being removed.

Hold Up Time

20mS, typ (Nom, Input, 100%)

DC Voltage Adjust (typ.)

±6%

Physical Specifications

Size (mm)

115.6 x 80.5 x 28 mm

Size (Inches)

4.55” x 3.17” x 1.50”

Construction

U-Channel

Weight (g)

291g

Weight (oz)

10.25oz

Notes

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.