130 Watts Output Power |
|
Single Outputs |
|
Universal 90-264VAC Input |
|
5VDC to 48VDC Outputs |
|
4646VDC Input to Output Isolation |
|
Active Power Factor Correction |
PMK130S 130 Watt Power Supplies
Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Efficiency |
Capacitive Load |
5 VDC |
22 Amps |
100mV pk-pk |
75% / 80% |
10,000uF | |
12 VDC |
10.8 Amps |
120mV pk-pk |
80% / 82% |
26,800uF | |
15 VDC |
8.7 Amps |
120mV pk-pk |
80% / 85% |
22,000uF | |
24 VDC |
5.4 Amps |
120mV pk-pk |
82% / 85% |
28,000uF | |
28 VDC |
4.6 Amps |
120mV pk-pk |
82% / 85% |
16,800uF | |
36 VDC |
3.6 Amps |
120mV pk-pk |
82% / 85% |
1,950uF | |
48 VDC |
2.7 Amps |
120mV pk-pk |
82% / 85% |
7,800uF |
Triple Output
Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Efficiency |
Capacitive Load |
5/12/-12 VDC |
15/5/1 Amps |
100/120/120mV pk-pk |
75% / 80% |
25,000uF | |
5/15/-15 VDC |
15/5/1 Amps |
100/150/150mV pk-pk |
75% / 80% |
25,000uF | |
5/24/12 VDC |
4/4/2 Amps |
100/240/120mV pk-pk |
75% / 80% |
25,000uF | |
| 12/24/5 VDC | 8/2/3 Amps | 12/240/1000mV pk-pk | 75% / 80% | 15,000uF |
Note:
1. The PMK130 Series is offered in an optional U-Channel Chassis as well as with optional 3.96mm pitch 5 and 10 Pin Input and Output connectors (open frame construction and screw termainals are standard respectively). Simply add a "U" at the end of the Model Number to receive the U-Channel configuration or a "-A" to receive the pins, or both if both are desired. For example: The Model Number "PMK130T-AU-A" represents a triple output (5/12/-12VDC) U-Channel supply with 3.96 pitched pins (5 Input; 10 Output). See the Mechanical Dimensions on the Specification Sheet.
2. PMMK130T-A and all "U" options are not covered by UL Certification unless provided with more than 10 CFM forced air cooling applied 6-10cm above T1.
3. Derating curves acceptable up to 40°C for UL certified products.
PMK130S series
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |